An integrated microfluidic 3D tumor system for parallel and high-throughput chemotherapy evaluation?
Analyst Pub Date: 2020-08-14 DOI: 10.1039/D0AN01229G
Abstract
The development of a microplatform with multifunctional integration allowing the dynamic and high-throughput exploration of three-dimensional (3D) cultures is promising for biomedical research. Here, we introduce an integrated microfluidic 3D tumor system with pneumatic manipulation and chemical gradient generation to investigate anticancer therapy in a parallel, controllable, dynamic, and high-throughput manner. The stability of the microfluidic system to realize precise and long-term chemical gradient production was developed. Serial manipulations including active cell trapping, array-like tumor self-assembly and formation, reliable gradient generation, parallel multi-concentration drug stimulation, and real-time tumor analysis were achieved in a single microfluidic device. The microfluidic platform was demonstrated to be stable for high-throughput cell trapping and 3D tumor formation with uniform quantities. On-chip analysis of phenotypic tumor responses to diverse chemotherapies with different concentrations can be conducted in this device. The microfluidic advancement holds great potential for applications in the development of high-performance and multi-functional biomimetic tumor systems and in the fields of cancer research and pharmaceutical development.
Recommended Literature
- [1] An ion-exchange method for determining paraquat residues in food crops Analyst, 1965,90, 99-106 10.1039/AN9659000099
- [2] Aggregation-induced emission leading to two distinct emissive species in the solid-state structure of high-dipole organic chromophores? Felix Witte,Philipp Rietsch,Nithiya Nirmalananthan-Budau,Florian Weigert,Jan P. G?tze,Ute Resch-Genger,Siegfried Eigler,Beate PaulusPhys. Chem. Chem. Phys., 2021,23, 17521-17529 10.1039/D1CP02534A
- [3] An aquatic host–guest complex between a supramolecular G-quadruplex and the anticancer drug doxorubicin? José M. Rivera,Mariana Martín-Hidalgo,Jean C. Rivera-RíosOrg. Biomol. Chem., 2012,10, 7562-7565 10.1039/C2OB25913C
- [4] An alternative biorefinery approach to address microalgal seasonality: blending with spent coffee grounds Andre Prates Pereira,Tao Dong,Eric P. Knoshaug,Nick Nagle,Ryan Spiller,Bonnie Panczak,Christopher J. Chuck,Philip T. PienkosSustainable Energy Fuels, 2020,4, 3400-3408 10.1039/D0SE00164C
- [5] An approach to 7-aza-1-phosphanorbornane complexes: strain promoted rearrangement of 1-iminylphosphirane complexes and cycloaddition with olefins? Yang Xu,Min Wang,Donghui Wei,Rongqiang Tian,Zheng Duan,Fran?ois MatheyDalton Trans., 2019,48, 5523-5526 10.1039/C9DT00838A
- [6] An all-solid-state asymmetric device based on a polyaniline hydrogel for a high energy flexible supercapacitor? Hamid Heydari,Mohammad B. GholivandNew J. Chem., 2017,41, 237-244 10.1039/C6NJ02266A
- [7] An integrated digital microfluidic chip for multiplexed proteomic sample preparation and analysis by MALDI-MS? Hyejin Moon,Aaron R. Wheeler,Robin L. Garrell,Chang-Jin “CJ” KimLab Chip, 2006,6, 1213-1219 10.1039/B601954D
- [8] An intramolecular tryptophan-condensation approach for peptide stapling? Eunice Y.-L. Hui,Bhimsen Rout,Yaw Sing Tan,Kok-Ping Chan,Charles W. JohannesOrg. Biomol. Chem., 2018,16, 389-392 10.1039/C7OB02667F
- [9] An atom-economical protocol for direct conversion of Baylis–Hillman alcohols to β-chloro aldehydes in water? Raktani Bikshapathi,Sai Prathima Parvathaneni,Vaidya Jayathirtha RaoGreen Chem., 2017,19, 4446-4450 10.1039/C7GC01483J
- [10] An amphipathic trans-acting phosphorothioate RNA element delivers an uncharged phosphorodiamidate morpholino sequence in mdx mouse myotubes? H. V. Jain,D. Verthelyi,S. L. BeaucageRSC Adv., 2017,7, 42519-42528 10.1039/C7RA04247G
Journal Name:Analyst
research_products
-
CAS no.: 89640-58-4