Chemical clocks, oscillations, and other temporal effects in analytical chemistry: oddity or viable approach?
Analyst Pub Date: 2018-05-22 DOI: 10.1039/C7AN01926B
Abstract
Most analytical methods are based on “analogue” inputs from sensors of light, electric potentials, or currents. The signals obtained by such sensors are processed using certain calibration functions to determine concentrations of the target analytes. The signal readouts are normally done after an optimised and fixed time period, during which an assay mixture is incubated. This minireview covers another—and somewhat unusual—analytical strategy, which relies on the measurement of time interval between the occurrences of two distinguishable states in the assay reaction. These states manifest themselves via abrupt changes in the properties of the assay mixture (e.g. change of colour, appearance or disappearance of luminescence, change in pH, variations in optical activity or mechanical properties). In some cases, a correlation between the time of appearance/disappearance of a given property and the analyte concentration can be also observed. An example of an assay based on time measurement is an oscillating reaction, in which the period of oscillations is linked to the concentration of the target analyte. A number of chemo-chronometric assays, relying on the existing (bio)transformations or artificially designed reactions, were disclosed in the past few years. They are very attractive from the fundamental point of view but—so far—only few of them have be validated and used to address real-world problems. Then, can chemo-chronometric assays become a practical tool for chemical analysis? Is there a need for further development of such assays? We are aiming to answer these questions.
Recommended Literature
- [1] An apparatus for determining small amounts of alchohol in sour milk and urine Analyst, 1964,89, 272-275 10.1039/AN9648900272
- [2] An astrophysically-relevant mechanism for amino acid enantiomer enrichment Stephen P. Fletcher,Richard B. C. Jagt,Ben L. FeringaChem. Commun., 2007, 2578-2580 10.1039/B702882B
- [3] An aquatic host–guest complex between a supramolecular G-quadruplex and the anticancer drug doxorubicin? José M. Rivera,Mariana Martín-Hidalgo,Jean C. Rivera-RíosOrg. Biomol. Chem., 2012,10, 7562-7565 10.1039/C2OB25913C
- [4] An apparatus for testing water by measurement of its electrical conductivity Analyst, 1912,37, 538-543 10.1039/AN9123700538
- [5] An amphipathic trans-acting phosphorothioate RNA element delivers an uncharged phosphorodiamidate morpholino sequence in mdx mouse myotubes? H. V. Jain,D. Verthelyi,S. L. BeaucageRSC Adv., 2017,7, 42519-42528 10.1039/C7RA04247G
- [6] An amorphous lanthanum–iridium solid solution with an open structure for efficient water splitting? Wei Sun,Chenglong Ma,Xinlong Tian,Jianjun Liao,Ji Yang,Chengjun Ge,Weiwei HuangJ. Mater. Chem. A, 2020,8, 12518-12525 10.1039/D0TA03351K
- [7] An Assessment of the Laminar Hypersonic Double-Cone Experiments in the LENS-XX Tunnel JaideepRay,PatrickBlonigan,EricT.Phipps,KathrynMaupin 10.2514/1.j062802
- [8] An anti-leakage liquid metal thermal interface material Kaiyuan Huang,Wangkang Qiu,Meilian Ou,Xiaorui Liu,Zenan Liao,Sheng ChuRSC Adv., 2020,10, 18824-18829 10.1039/D0RA02351E
- [9] An investigation of the electrochemical delithiation process of carbon coated α-Fe2O3nanoparticles Adrian Brandt,Florian Winter,Sebastian Klamor,Frank Berkemeier,Jatinkumar Rana,Rainer P?ttgen,Andrea BalducciJ. Mater. Chem. A, 2013,1, 11229-11236 10.1039/C3TA11821E
- [10] An analyte-triggered artificial peroxidase system based on dimanganese complex for a versatile enzyme assay? Suji Lee,Min Su HanChem. Commun., 2021,57, 9450-9453 10.1039/D1CC03638F
Journal Name:Analyst
research_products
-
CAS no.: 89640-58-4