Application of ion chromatography to the analysis of lead–acid battery electrolyte
Analyst Pub Date: DOI: 10.1039/A708670I
Abstract
Stringent specifications are laid down for the sulfuric acid used as battery electrolyte. In the present work ion chromatography (IC) was applied to the determination of several species in sulfuric acid and it proved possible to separate impurities in the presence of large amounts of sulfate ion without the need for a preconcentration or pre-separation step. Fluoride, chloride, bromide, nitrate, phosphate, sodium, potassium, magnesium, calcium, iron, copper, nickel, zinc and cadmium can easily be determined by diluting the lead–acid battery electrolyte (usually 38% H2SO4) 40-fold. Most of the species to be determined were found to be adversely affected by sample pre-treatments, such as sulfate precipitation or ion-exchange resin separation. The pH of the analyte strongly affects the analytical response and hence the optimum pH range was established for anions, alkali and alkaline earth metals, and transition metals. In the presence of organic compounds, oxidative UV photolysis of the sample permits determinations to be performed without any interference. The proposed procedure involves the IC determination of fluoride, chloride, bromide, nitrate, and phosphate using a carbonate–hydrogencarbonate eluent with suppressed conductivity detection, that of sodium, potassium, magnesium and calcium using a hydrochloric acid–2,3-diaminopropionic acid hydrochloride eluent with suppressed conductivity detection and that of iron, copper, nickel, zinc and cadmium using pyridine-2,6-dicarboxylic acid as eluent with visible absorbance detection. Detection limits ranged between 0.2 and 1.3 ppm and the linearity of the calibration graphs was found to be extended by up to two orders of magnitude.
Recommended Literature
- [1] An insight into the role of side chains in the microstructure and carrier mobility of high-performance conjugated polymers? Jianyao Huang,Dong Gao,Zhihui Chen,Weifeng ZhangPolym. Chem., 2021,12, 2471-2480 10.1039/D1PY00105A
- [2] An aqueous ammonia sensor based on an inkjet-printed polyaniline nanoparticle-modified electrode Karl Crowley,Eimer O'Malley,Aoife Morrin,Malcolm R. Smyth,Anthony J. KillardAnalyst, 2008,133, 391-399 10.1039/B716154A
- [3] Acentric and chiral heterometallic inorganic–organic hybrid frameworks mediated by alkali or alkaline earth ions: synthesis and NLO properties Huabin Zhang,Shaowu DuCrystEngComm, 2014,16, 4059-4068 10.1039/C3CE42419G
- [4] An investigation on the second-order nonlinear optical response of cationic bipyridine or phenanthroline iridium(iii) complexes bearing cyclometallated 2-phenylpyridines with a triphenylamine substituent? David B. Cordes,Alexandra M. Z. Slawin,Stefania Righetto,Denis Jacquemin,Eli Zysman-Colman,Véronique GuerchaisDalton Trans., 2018,47, 8292-8300 10.1039/C8DT00754C
- [5] Alternative mixtures to R-600a. Theoretical assessment and experimental energy evaluation of binary mixtures in a commercial cooler: Mélanges alternatifs au R-600a. évaluation théorique et évaluation énergétique expérimentale de mélanges binaires dans un refroidisseur commercial. DanielCalleja-Anta,DanielSánchez,LauraNebot-Andres,RamónCabello,RodrigoLlopis 10.1016/j.ijrefrig.2023.05.009
- [6] An investigation into the origin of variations in photovoltaic performance using D–D–π–A and D–A–π–A triphenylimidazole dyes with a copper electrolyte? Govind ReddyMol. Syst. Des. Eng., 2021,6, 779-789 10.1039/D1ME00073J
- [7] An intramolecular tryptophan-condensation approach for peptide stapling? Eunice Y.-L. Hui,Bhimsen Rout,Yaw Sing Tan,Kok-Ping Chan,Charles W. JohannesOrg. Biomol. Chem., 2018,16, 389-392 10.1039/C7OB02667F
- [8] An asymmetric supercapacitor based on controllable WO3 nanorod bundle and alfalfa-derived porous carbon? Kanjun Sun,Fengting Hua,Shuzhen Cui,Yanrong Zhu,Hui Peng,Guofu MaRSC Adv., 2021,11, 37631-37642 10.1039/D1RA04788D
- [9] An integrated droplet-digital microfluidic system for on-demand droplet creation, mixing, incubation, and sorting? Lab Chip, 2019,19, 524-535 10.1039/C8LC01170B
- [10] An integrated microfluidic platform for sensitive and rapid detection of biological toxins? Robert J. Meagher,Anson V. Hatch,Ronald F. Renzi,Anup K. SinghLab Chip, 2008,8, 2046-2053 10.1039/B815152K
Journal Name:Analyst
research_products
-
CAS no.: 89640-58-4