Application of poly(vinyl chloride) pilocarpine membrane electrodes in ophthalmic products
ANALYSTANALYST Pub Date: DOI: 10.1039/AN9941902327
Abstract
The construction and evaluation of two types of electrodes sensitive to pilocarpine, without an inner reference solution, based on pilocarpine–tetrakis(4-chlorophenyl) borate (Type I) and pilocarpine–tetrakis[3,5-bis(trifluoromethyl)-phenyl] borate (Type II) are described. The ion exchangers were dissolved in 2-nitrophenyl octyl ether and the resulting sensor solution was immobilized in poly(vinyl chloride)(PVC). Under similar experimental conditions, the calibration graphs for electrodes of Types I and II were linear in the concentration ranges between 3.0 × 10–5 and 6.0 × 10–5 to 0.1 mol dm–3(I= 0.1 mol dm–3 and pH = 6.3), respectively. The slopes of the calibration lines were close to the theoretical value and indistinguishable from each other. The reproducibilities of the potential for the two types of electrodes were similar, and approximately ±2 mV throughout a working day. The response time was better than 10 s for pilocarpine concentrations between 10–4 and 10–2 mol dm–3 for both types of electrodes. Both types of electrodes were in operation for a period exceeding 7 months. The electrodes exhibited useful analytical characteristics for the determination of pilocarpine in pharmaceutical products. Direct potentiometric calculations in solutions with a concentration of pilocarpine hydrochloride of about 48 μg cm–3 showed mean recoveries between 106 and 98% for determinations carried out with Type I electrodes and between 93 and 101% with Type II electrodes.
Recommended Literature
- [1] An asymmetric supercapacitor based on controllable WO3 nanorod bundle and alfalfa-derived porous carbon? Kanjun Sun,Fengting Hua,Shuzhen Cui,Yanrong Zhu,Hui Peng,Guofu MaRSC Adv., 2021,11, 37631-37642 10.1039/D1RA04788D
- [2] Acetyl protected thiol methacrylic polymers as effective ligands to keep quantum dots in luminescent standby mode? Marta Liras,Isabel Quijada-Garrido,Marta Palacios-Cuesta,Sonia Mu?oz-Durieux,Olga GarcíaPolym. Chem., 2014,5, 433-442 10.1039/C3PY00987D
- [3] Alternative donor substrates for inverting and retaining glycosyltransferases? Luke L. Lairson,Warren W. WakarchukChem. Commun., 2007, 365-367 10.1039/B614636H
- [4] An aptamer-based keypad lock system? Yaqing Liu,Jiangtao Ren,Jing Li,Jiyang Liu,Erkang WangChem. Commun., 2012,48, 802-804 10.1039/C1CC15979H
- [5] An apparatus for testing water by measurement of its electrical conductivity Analyst, 1912,37, 538-543 10.1039/AN9123700538
- [6] An amorphous carbon nitride/NiO/CoN-based composite: a highly efficient nonprecious electrode for supercapacitors and the oxygen evolution reaction? Huifang Yang,Haoran Guo,Peidong Fan,Xinpan Li,Wenlu Ren,Rui SongNanoscale, 2020,12, 7024-7034 10.1039/D0NR00001A
- [7] An inter-tangled network of redox-active and conducting polymers as a cathode for ultrafast rechargeable batteries Jieun Kim,Han-Saem Park,Tae-Hee Kim,Sung Yeol Kim,Hyun-Kon SongPhys. Chem. Chem. Phys., 2014,16, 5295-5300 10.1039/C3CP54624A
- [8] An all-solid-state asymmetric device based on a polyaniline hydrogel for a high energy flexible supercapacitor? Hamid Heydari,Mohammad B. GholivandNew J. Chem., 2017,41, 237-244 10.1039/C6NJ02266A
- [9] Alt-proteins: A promising future 10.1002/fsat.3701_10.x
- [10] An artificial photosynthetic system for photoaccumulation of two electrons on a fused dipyridophenazine (dppz)–pyridoquinolinone ligand? Philipp Traber,Stephan Kupfer,Stefanie Gr?fe,Isabelle Baussanne,Martine Demeunynck,Jean-Marie Mouesca,Serge Gambarelli,Vincent Artero,Murielle Chavarot-KerlidouChem. Sci., 2018,9, 4152-4159 10.1039/C7SC04348A
Journal Name:ANALYSTANALYST
research_products
-
CAS no.: 89640-58-4