Reaction screening and optimization of continuous-flow atropine synthesis by preparative electrospray mass spectrometry?
Analyst Pub Date: 2017-06-21 DOI: 10.1039/C7AN00622E
Abstract
Preparative electrospray (ES) exploits the acceleration of reactions in charged microdroplets to perform a small scale chemical synthesis. In combination with on-line mass spectrometric (MS) analysis, it constitutes a rapid screening tool to select reagents to generate specific products. A successful reaction in preparative ES triggers a refined microfluidic reaction screening procedure which includes the optimization for stoichiometry, temperature and residence time. We apply this combined approach for refining a flow synthesis of atropine. A successful preparative ES pathway for the synthesis of the phenylacetyl ester intermediate, using tropine/HCl/phenylacetyl chloride, was optimized for solvent in both the preparative ES and microfluidics flow systems and a base screening was conducted by both methods to increase atropine yield, increase percentage conversion and reduce byproducts. In preparative ES, the first step yielded 55% conversion (judged using MS) to intermediate and the second step yielded 47% conversion to atropine. When combined in two discrete steps in continuous-flow microfluidics, a 44% conversion of the starting material and a 30% actual yield of atropine were achieved. When the reactions were continuously telescoped in a new form of preparative reactive extractive electrospray (EES), atropine was synthesized with a 24% conversion. The corresponding continuous-flow microfluidics experiment gave a 55% conversion with an average of 34% yield in 8 min residence time. This is the first in depth study to utilize telescoped preparative ES and the first use of dual ESI emitters for multistep synthesis.
Recommended Literature
- [1] Aggregation dynamics, structure, and mechanical properties of bigels L. Di Michele,D. Fiocco,F. Varrato,E. Eiser,G. FoffiSoft Matter, 2014,10, 3633-3648 10.1039/C3SM52558A
- [2] An atmosphere and light tuned highly diastereoselective synthesis of cyclobuta/penta[b]indoles from aniline-tethered alkylidenecyclopropanes with alkynes? Bo Cao,Yin WeiChem. Commun., 2018,54, 2870-2873 10.1039/C8CC00180D
- [3] An aptasensor for the detection of ampicillin in milk using a personal glucose meter Xixi Li,Nanwei Zhu,Ruohan Li,Qinpu ZhangAnal. Methods, 2020,12, 3376-3381 10.1039/D0AY00256A
- [4] An artificial photosynthetic system for photoaccumulation of two electrons on a fused dipyridophenazine (dppz)–pyridoquinolinone ligand? Philipp Traber,Stephan Kupfer,Stefanie Gr?fe,Isabelle Baussanne,Martine Demeunynck,Jean-Marie Mouesca,Serge Gambarelli,Vincent Artero,Murielle Chavarot-KerlidouChem. Sci., 2018,9, 4152-4159 10.1039/C7SC04348A
- [5] An artificial CO-releasing metalloprotein built by histidine-selective metallation? Inês S. Albuquerque,Hélia F. Jeremias,Miguel Chaves-Ferreira,Dijana Matak-Vinkovic,Omar Boutureira,Carlos C. Rom?oChem. Commun., 2015,51, 3993-3996 10.1039/C4CC10204E
- [6] An intramolecular tryptophan-condensation approach for peptide stapling? Eunice Y.-L. Hui,Bhimsen Rout,Yaw Sing Tan,Kok-Ping Chan,Charles W. JohannesOrg. Biomol. Chem., 2018,16, 389-392 10.1039/C7OB02667F
- [7] Acetyl protected thiol methacrylic polymers as effective ligands to keep quantum dots in luminescent standby mode? Marta Liras,Isabel Quijada-Garrido,Marta Palacios-Cuesta,Sonia Mu?oz-Durieux,Olga GarcíaPolym. Chem., 2014,5, 433-442 10.1039/C3PY00987D
- [8] An integrated digital microfluidic chip for multiplexed proteomic sample preparation and analysis by MALDI-MS? Hyejin Moon,Aaron R. Wheeler,Robin L. Garrell,Chang-Jin “CJ” KimLab Chip, 2006,6, 1213-1219 10.1039/B601954D
- [9] An autonomous self-optimizing flow machine for the synthesis of pyridine–oxazoline (PyOX) ligands? Eric Wimmer,Daniel Cortés-Borda,Solène Brochard,Elvina Barré,Charlotte Truchet,Fran?ois-Xavier FelpinReact. Chem. Eng., 2019,4, 1608-1615 10.1039/C9RE00096H
- [10] An analysis of the WTC fires using CIB correlations and simple modeling JGQuintiere 10.1177/0734904121989670
Journal Name:Analyst
research_products
-
CAS no.: 89640-58-4