A simple and rapid method for the determination of mercury in gas condensates by inductively coupled plasma-mass spectrometry
Analytical Methods Pub Date: 2015-01-02 DOI: 10.1039/C4AY02015D
Abstract
A method for the accurate determination of mercury content in gas condensates is of significance in the applications of condensates. In this paper, a simple and rapid method for the determination of mercury in gas condensates using inductively coupled plasma-mass spectrometry was established. The effects of experimental conditions including extraction reagent, sample mass, extraction time in water bath, and membrane filtration treatment were investigated. A sample mass of 1.00 g, 10 mL of aqua regia as pretreatment reagent, and boiling water bath time of 60 min were selected as the optimal pretreatment conditions. After hydrophilic membrane filtering, the obtained solution was diluted 10 times using 3% (v/v) nitric acid and the inductively coupled plasma-mass spectrometry determination was conducted. The method detection limit was 0.4 ng g?1, and the relative standard deviation range was from 2.8% to 5.4% for the samples of different natures. Both standard addition recovery experiments and comparison results with a microwave-assisted digestion method indicated that the proposed method was reliable for the determination of mercury in gas condensates.
Recommended Literature
- [1] An investigation of new infrared nonlinear optical material: BaCdSnSe4, and three new related centrosymmetric compounds: Ba2SnSe4, Mg2GeSe4, and Ba2Ge2S6? Kui Wu,Zhihua Yang,Shilie PanDalton Trans., 2015,44, 19856-19864 10.1039/C5DT03215F
- [2] An intramolecular tryptophan-condensation approach for peptide stapling? Eunice Y.-L. Hui,Bhimsen Rout,Yaw Sing Tan,Kok-Ping Chan,Charles W. JohannesOrg. Biomol. Chem., 2018,16, 389-392 10.1039/C7OB02667F
- [3] An atom-economical protocol for direct conversion of Baylis–Hillman alcohols to β-chloro aldehydes in water? Raktani Bikshapathi,Sai Prathima Parvathaneni,Vaidya Jayathirtha RaoGreen Chem., 2017,19, 4446-4450 10.1039/C7GC01483J
- [4] An artificial CO-releasing metalloprotein built by histidine-selective metallation? Inês S. Albuquerque,Hélia F. Jeremias,Miguel Chaves-Ferreira,Dijana Matak-Vinkovic,Omar Boutureira,Carlos C. Rom?oChem. Commun., 2015,51, 3993-3996 10.1039/C4CC10204E
- [5] Acentric and chiral heterometallic inorganic–organic hybrid frameworks mediated by alkali or alkaline earth ions: synthesis and NLO properties Huabin Zhang,Shaowu DuCrystEngComm, 2014,16, 4059-4068 10.1039/C3CE42419G
- [6] An apparatus for determining small amounts of alchohol in sour milk and urine Analyst, 1964,89, 272-275 10.1039/AN9648900272
- [7] An anti-ultrasonic-stripping effect in confined micro/nanoscale cavities and its applications for efficient multiscale metallic patterning? Quan Xiang,Yiqin Chen,Zhiqin Li,Kaixi Bi,Guanhua Zhang,Huigao DuanNanoscale, 2016,8, 19541-19550 10.1039/C6NR07585A
- [8] An artificial blood vessel implanted three-dimensional microsystem for modeling transvascular migration of tumor cells? Xue-Ying Wang,Ying Pei,Min Xie,Zi-He Jin,Ya-Shi Xiao,Yang Wang,Li-Na Zhang,Yan Li,Wei-Hua HuangLab Chip, 2015,15, 1178-1187 10.1039/C4LC00973H
- [9] An integrated chip for immunofluorescence and its application to analyze lysosomal storage disorders Jie Shen,Ying Zhou,Tu Lu,Junya Peng,Zhixiang Lin,Yuhong Pang,Li YuLab Chip, 2012,12, 317-324 10.1039/C1LC20845D
- [10] An anti-leakage liquid metal thermal interface material Kaiyuan Huang,Wangkang Qiu,Meilian Ou,Xiaorui Liu,Zenan Liao,Sheng ChuRSC Adv., 2020,10, 18824-18829 10.1039/D0RA02351E
Journal Name:Analytical Methods
research_products
-
CAS no.: 89640-58-4