Profiling of aldehyde-containing compounds by stable isotope labelling-assisted mass spectrometry analysis?
Analyst Pub Date: 2015-06-01 DOI: 10.1039/C5AN00657K
Abstract
We developed a strategy for non-targeted profiling of aldehyde-containing compounds by stable isotope labelling in combination with liquid chromatography–double neutral loss scan–mass spectrometry (SIL–LC–DNLS–MS) analysis. A pair of stable isotope labelling reagents (4-(2-(trimethylammonio)ethoxy)benzenaminium halide, 4-APC and d4-4-(2-(trimethylammonio)ethoxy)benzenaminium halide, 4-APC-d4) that can selectively label aldehyde-containing compounds were synthesized. The 4-APC and 4-APC-d4 labelled compounds were capable of generating two characteristic neutral fragments of 87 Da and 91 Da, respectively, under collision induced dissociation (CID). Therefore, double neutral loss scans were carried out simultaneously to record the signals of the potential aldehyde-containing compounds. In this respect, the aldehyde-containing compounds from two samples labelled with 4-APC and 4-APC-d4 were ionized at the same time but recorded separately by mass spectrometry. The peak pairs with characteristic mass differences (n × 4 Da) can be readily extracted from the DNLS spectra and assigned as potential aldehyde-containing candidates, which facilitates the identification of the target aldehydes. 4-APC and 4-APC-d4 labelling also dramatically increased detection sensitivities of the derivatives. Using the SIL–LC–DNLS–MS strategy, we successfully profiled the aldehyde-containing compounds in human urine and white wine. Our results showed that 16 and 19 potential aldehyde-containing compounds were discovered in human urine and white wine, respectively. In addition, 5 and 4 aldehyde-containing compounds in human urine and white wine were further identified by comparison with aldehyde standards. Altogether, SIL–LC–DNLS–MS demonstrated to be a promising approach in the identification and relative quantification of aldehyde-containing compounds from complex samples.
Recommended Literature
- [1] An Aptamer Bio-barCode (ABC) assay using SPR, RNase H, and probes with RNA and gold-nanorods for anti-cancer drug screening Chengbin Yang,Hing Lun Tsang,Pui Man Lau,Ken-Tye Yong,Ho Pui Ho,Siu Kai KongAnalyst, 2017,142, 3579-3587 10.1039/C7AN01026E
- [2] An automatic determination of thoria in thoria-urania mixtures Analyst, 1966,91, 208-210 10.1039/AN9669100208
- [3] An aquatic host–guest complex between a supramolecular G-quadruplex and the anticancer drug doxorubicin? José M. Rivera,Mariana Martín-Hidalgo,Jean C. Rivera-RíosOrg. Biomol. Chem., 2012,10, 7562-7565 10.1039/C2OB25913C
- [4] An AuNPs-functionalized AlGaN/GaN high electron mobility transistor sensor for ultrasensitive detection of TNT? Ying Li,Weirong Yao,Yunfei Xie,Renjun PeiRSC Adv., 2015,5, 98724-98729 10.1039/C5RA16704C
- [5] An intermolecular C–C coupling reaction of iridium complexes? Kathrin Kutlescha,Rhett KempeNew J. Chem., 2010,34, 1954-1960 10.1039/C0NJ00158A
- [6] An investigation on the second-order nonlinear optical response of cationic bipyridine or phenanthroline iridium(iii) complexes bearing cyclometallated 2-phenylpyridines with a triphenylamine substituent? David B. Cordes,Alexandra M. Z. Slawin,Stefania Righetto,Denis Jacquemin,Eli Zysman-Colman,Véronique GuerchaisDalton Trans., 2018,47, 8292-8300 10.1039/C8DT00754C
- [7] An ionic liquid-based synergistic extraction strategy for rare earths? Yingbo Li,Nada Mehio,Huizhou Liu,Sheng DaiGreen Chem., 2015,17, 2981-2993 10.1039/C5GC00360A
- [8] Achieving excellent anti-corrosion and tribological performance by tailoring the surface morphology and chemical composition of aluminum alloys Wenjie Zhao,Hua Hou,Yuchun Jin,Zhixiang Zeng,Xuedong Wu,Qunji XueRSC Adv., 2014,4, 60307-60315 10.1039/C4RA10112J
- [9] An interplay between electronic and structural effects on the photoluminescence decay mechanisms in LaPO4·nH2O:Tb3+ and LaPO4:Tb3+ single-crystal nanorods? M. T. Colomer,S. Díaz-Moreno,A. Tamayo,A. L. OrtizJ. Mater. Chem. C, 2018,6, 12643-12651 10.1039/C8TC03187H
- [10] An integrated process of CO2 capture and in situ hydrogenation to formate using a tunable ethoxyl-functionalized amidine and Rh/bisphosphine system? Yu-Nong Li,Liang-Nian He,Xian-Dong Lang,Xiao-Fang Liu,Shuai ZhangRSC Adv., 2014,4, 49995-50002 10.1039/C4RA08740B
Journal Name:Analyst
research_products
-
CAS no.: 89640-58-4