A paper-based sensor for rapid and ultrasensitive detection of ibuprofen in water and herbal tea
Analyst Pub Date: 2021-09-15 DOI: 10.1039/D1AN01533H
Abstract
As the use of non-steroidal anti-inflammatory drugs (NSAIDS) increases, their side effects have also attracted attention. Ibuprofen is one of the most widely-used NSAIDs. In this study, we screened the highly-sensitive and specific antibody 6E10, with an IC50 of 1.92 ng mL?1, and a linear range of 0.53–6.97 ng mL?1. In this study, we developed a rapid lateral flow immunochromatographic assay (ICA) strip method to detect ibuprofen in water or herbal tea. The cut-off limit of the strip is 10 ng mL?1 in water, and concentrations as low as 1 ng mL?1 can be detected in herbal tea samples, with the results obtained by the naked eye within 6 min. All the data were confirmed by high performance liquid chromatography-quadrupole time of flight-mass spectrometry (HPLC-QTOF-MS). This lateral-flow ICA strip is thus a rapid tool for on-site detection and screening of ibuprofen in water and herbal tea.
Recommended Literature
- [1] Fatty acid eutectic mixtures and derivatives from non-edible animal fat as phase change materials? Pau Gallart-Sirvent,Marc Martín,Gemma Villorbina,Mercè Balcells,Aran Solé,Luisa F. Cabeza,Ramon Canela-GarayoaRSC Adv., 2017,7, 24133-24139 10.1039/C7RA03845C
- [2] Exchangeability of amino acid residues with similar physicochemical properties in coiled-coil interactions? Guiying Zhang,Maosheng Cheng,Yanni Li,Keliang Liu,Lifeng CaiChem. Commun., 2013,49, 11086-11088 10.1039/C3CC46560H
- [3] Evolution and characterization of a benzylguanine-binding RNA aptamer? J. Xu,T. J. Carrocci,A. A. HoskinsChem. Commun., 2016,52, 549-552 10.1039/C5CC07605F
- [4] Exciplex emission from the mixed dimer of naphthalene and 2-cyanonaphthalene in a supersonic jet Aloke Das,K. K. Mahato,Chayan K. Nandi,Tapas Chakraborty,Shridhar R. Gadre,Nikhil A. GokhalePhys. Chem. Chem. Phys., 2002,4, 2162-2168 10.1039/B200124C
- [5] Emerging investigator series: bacteriophages as nano engineering tools for quality monitoring and pathogen detection in water and wastewater Fereshteh BayatEnviron. Sci.: Nano, 2021,8, 367-389 10.1039/D0EN00962H
- [6] Establishing the accuracy of position-specific carbon isotope analysis of propane by GC-pyrolysis-GC-IRMS ChangjieLiu,PengLiu,XiaofengWang,XiaoqiangLi,JuskeHorita 10.1002/rcm.9494
- [7] Enabling high-throughput single-animal gene-expression studies with molecular and micro-scale technologies Jason WanLab Chip, 2020,20, 4528-4538 10.1039/D0LC00881H
- [8] Fast-Track to Research Data Management in Experimental Material Science-Setting the Ground for Research Group Level Materials Digitalization. LarsBanko,AlfredLudwig 10.1021/acscombsci.0c00057
- [9] Exchanged ligands on the surface of a giant cluster: [(MoO3)176(H2O)63(CH3OH)17Hn](32 – n)– Chem. Commun., 1998, 1501-1502 10.1039/A801804I
- [10] Fc microparticles can modulate the physical extent and magnitude of complement activity? David White,Sean R. StowellBiomater. Sci., 2017,5, 463-474 10.1039/C6BM00608F
Journal Name:Analyst
research_products
-
CAS no.: 89640-58-4