High-performance liquid chromatographic assay of ampicillin, amoxicillin and ciclacillin in serum and urine using a pre-column reaction with 1,2,4-triazole and mercury(II) chloride
ANALYSTANALYST Pub Date: DOI: 10.1039/AN9851001277
Abstract
High-performance liquid chromatographic methods have been developed for the determination of ampicillin (ABPC), amoxicillin (AMPC) and ciclacillin (ACPC) in serum and urine. The methods involve acetylation of these aminopenicillins with acetic anhydride in aqueous solutions (pH 9.0) at ambient temperature for 3 min followed by reaction with 2 M 1,2,4-triazole and 10–3M mercury(II) chloride in solution (pH 9.0) at 60 °C for 10 min. The resulting products were separated on a C18 column following stabilisation in an eluent containing sodium thiosulphate. They were detected at 328 nm for ABPC and AMPC and 327 nm for ACPC.
The methods have been applied to assays of these aminopenicillins in serum and urine. The procedures, which permit the accurate determination of aminopenicillin concentrations in serum down to 0.05 μg ml–1 for AMPC and 0.1 μg ml–1 for ABPC and ACPC, are specific to intact penicillins without interference from the corresponding penicilloates. At an aminopenicillin concentration of 1 μg ml–1 in serum, the within- and between-run precisions were 0.97–3.51% and 2.07–3.55%, respectively.
Recommended Literature
- [1] An atomically efficient, highly stable and redox active Ce0.5Tb0.5Ox (3% mol.)/MgO catalyst for total oxidation of methane? Juan J. Sánchez,Miguel López-Haro,Juan C. Hernández-Garrido,Ginesa Blanco,Miguel A. Cauqui,José M. Rodríguez-Izquierdo,José A. Pérez-Omil,José J. Calvino,María P. YesteJ. Mater. Chem. A, 2019,7, 8993-9003 10.1039/C8TA11672E
- [2] An approach to biodegradable star polymeric architectures using disulfide coupling? Jingquan Liu,Huiyun Liu,Zhongfan Jia,Volga Bulmus,Thomas P. DavisChem. Commun., 2008, 6582-6584 10.1039/B817037A
- [3] Alternative donor substrates for inverting and retaining glycosyltransferases? Luke L. Lairson,Warren W. WakarchukChem. Commun., 2007, 365-367 10.1039/B614636H
- [4] An integrated system for field analysis of Cd(ii) and Pb(ii) via preconcentration using nano-TiO2/cellulose paper composite and subsequent detection with a portable X-ray fluorescence spectrometer? Xiaofeng LinRSC Adv., 2016,6, 9002-9006 10.1039/C5RA25693C
- [5] Aggregated-fluorescent detection of PFAS with a simple chip Cheng Fang,Jinjian Wu,Zahra Sobhani,Md. Al Amin,Youhong TangAnal. Methods, 2019,11, 163-170 10.1039/C8AY02382D
- [6] An artificial CO-releasing metalloprotein built by histidine-selective metallation? Inês S. Albuquerque,Hélia F. Jeremias,Miguel Chaves-Ferreira,Dijana Matak-Vinkovic,Omar Boutureira,Carlos C. Rom?oChem. Commun., 2015,51, 3993-3996 10.1039/C4CC10204E
- [7] An atomic scale study of defects in Co2FeAl Ravi Kumar Yadav,R. GovindarajPhys. Chem. Chem. Phys., 2020,22, 26876-26886 10.1039/D0CP04572A
- [8] An approach for correlating the structural and electrical properties of Zr4+-modified SrBi4Ti4O15/SBT ceramic Priyambada Nayak,Tanmaya Badapanda,Anil Kumar Singh,Simanchalo PanigrahiRSC Adv., 2017,7, 16319-16331 10.1039/C7RA00366H
- [9] An amino group functionalized metal–organic framework as a luminescent probe for highly selective sensing of Fe3+ ions? Zhonghua Xiang,Chuanqi Fang,Sanhua Leng,Dapeng CaoJ. Mater. Chem. A, 2014,2, 7662-7665 10.1039/C4TA00313F
- [10] An approach to the structure and vibrational analysis of cis- and trans-3-chlorostyrene through IR/Raman and INS spectroscopies and theoretical ab initio/DFT calculations? J. M. Granadino-Roldán,M. Fernández-Gómez,A. Navarro,T. Pe?a Ruiz,U. A. JayasooriyaPhys. Chem. Chem. Phys., 2004,6, 1133-1143 10.1039/B314243D
Journal Name:ANALYSTANALYST
research_products
-
CAS no.: 89640-58-4