Disposable biogenic amine biosensors for histamine determination in fish?
Analytical MethodsANAL METHODS-UK Pub Date: 2020-06-24 DOI: 10.1039/D0AY00802H
Abstract
This study presents the development of disposable biosensors employed in the determination of histamine in fish samples. Screen printed carbon electrodes (SPCEs) were first modified with a mixture of titanium dioxide nanoparticles (TiO2), carboxylated multiwalled carbon nanotubes (c-MWCNTs), hexaammineruthenium(III) chloride (RU) and chitosan (CS). Diamine oxidase (DAO) or monoamine oxidase (MAO) enzymes were further immobilized onto the TiO2–c-MWCNT–RU–CS/SPCEs via 1-ethyl-3-(dimethylaminopropyl) carbodiimide hydrochloride (EDC) and hydroxysuccinimide (NHS) chemistry for the fabrication of the biosensors. The morphological and electrochemical properties of the proposed biosensors were studied using scanning electron microscopy (SEM), energy dispersive X-ray (EDX) spectroscopy, cyclic voltammetry (CV), chronoamperometry and electrochemical impedance spectroscopy (EIS). A performance comparison of two biosensors indicated that the one based on DAO had a linear concentration range from 9.9 × 10?6 to 1.1 × 10?3 M and the other based on MAO, from 5.6 × 10?5 to 1.1 × 10?3 M for histamine. The sensitivity of the DAO based biosensor was almost 1.5 times higher than that of the MAO based biosensor. The proposed biosensors were successfully employed to determine histamine in fish samples and the recoveries were between 100.0% and 104.6%.
Recommended Literature
- [1] Ester-directed orthogonal dual C–H activation and ortho aryl C–H alkenylation via distal weak coordination? Manickam Bakthadoss,Tadiparthi Thirupathi Reddy,Vishal Agarwal,Duddu S. SharadaChem. Commun., 2022,58, 1406-1409 10.1039/D1CC06097J
- [2] Establishment and implications of a characterization method for magnetic nanoparticle using cell tracking velocimetry and magnetic susceptibility modified solutions Huading Zhang,Lee R. Moore,Maciej Zborowski,P. Stephen Williams,Shlomo Margel,Jeffrey J. ChalmersAnalyst, 2005,130, 514-527 10.1039/B412723D
- [3] EWOD-driven droplet microfluidic device integrated with optoelectronic tweezers as an automated platform for cellular isolation and analysis? Gaurav J. Shah,Eric P.-Y. Chiou,Ming C. Wu,Chang-Jin “CJ” KimLab Chip, 2009,9, 1732-1739 10.1039/B821508A
- [4] Fate of Sb(v) and Sb(iii) species along a gradient of pH and oxygen concentration in the Carnoulès mine waters (Southern France) Eléonore Resongles,Corinne Casiot,Fran?oise Elbaz-Poulichet,Rémi Freydier,Odile Bruneel,Christine Piot,Sophie Delpoux,Aurélie Volant,Angélique DesoeuvreEnviron. Sci.: Processes Impacts, 2013,15, 1536-1544 10.1039/C3EM00215B
- [5] Distinct correlation between (CN2)x units and pores: a low-cost method for predesigned wide range control of micropore size of porous carbon? Xiaotong Feng,Lei Bian,Jie Ma,Lei Zhou,Xiayan Wang,Guangsheng Guo,Qiaosheng PuChem. Commun., 2019,55, 3963-3966 10.1039/C9CC01213C
- [6] Excitable dynamics in the bromate–sulfite–ferrocyanide reaction J. Zagora,M. Vosla?,L. Schreiberová,I. SchreiberPhys. Chem. Chem. Phys., 2002,4, 1284-1291 10.1039/B110048C
- [7] Enabling non-flammable Li-metal batteries via electrolyte functionalization and interface engineering? Jing Yu,Yu-Qi Lyu,Jiapeng Liu,Mohammed B. Effat,Junxiong WuJ. Mater. Chem. A, 2019,7, 17995-18002 10.1039/C9TA03784E
- [8] Dissociative dynamics of O2 on Ag(110)? Ivor Lon?ari?Phys. Chem. Chem. Phys., 2015,17, 9436-9445 10.1039/C4CP05900J
- [9] Establishing the accuracy of position-specific carbon isotope analysis of propane by GC-pyrolysis-GC-IRMS ChangjieLiu,PengLiu,XiaofengWang,XiaoqiangLi,JuskeHorita 10.1002/rcm.9494
- [10] Emulsion soft templating of carbide-derived carbon nanospheres with controllable porosity for capacitive electrochemical energy storage? M. Zeiger,N. J?ckel,P. Strubel,L. Borchardt,R. Reinhold,W. Nickel,J. Eckert,V. Presser,S. KaskelJ. Mater. Chem. A, 2015,3, 17983-17990 10.1039/C5TA03730A
Journal Name:Analytical MethodsANAL METHODS-UK
research_products
-
CAS no.: 89640-58-4