Determination of ivermectin in feeds by high-performance liquid chromatography
ANALYSTANALYST Pub Date: DOI: 10.1039/AN9851000259
Abstract
A direct high-performance liquid chromatographic method has been developed for the determination of ivermectin in feeds over the concentration range 50–500 mg kg–1. Sample preparation is based upon extraction into methanol and separation of interferences on a gravity-fed alumina (activity III) column in advance of introduction into a standard reversed-phase chromatographic system. Experiments are described to document the efficiency of this sample preparation scheme and the chemical yield of the analyte through the process. The method has been applied to three types of feed samples with an accuracy of ±3.4% mean relative error and a relative standard deviation (precision) of <3%. It has a lower limit of detection with a signal to noise ratio
2 : 1 of 6.0 mg kg–1 of ivermectin.
Recommended Literature
- [1] An anti-ultrasonic-stripping effect in confined micro/nanoscale cavities and its applications for efficient multiscale metallic patterning? Quan Xiang,Yiqin Chen,Zhiqin Li,Kaixi Bi,Guanhua Zhang,Huigao DuanNanoscale, 2016,8, 19541-19550 10.1039/C6NR07585A
- [2] An astrophysically-relevant mechanism for amino acid enantiomer enrichment Stephen P. Fletcher,Richard B. C. Jagt,Ben L. FeringaChem. Commun., 2007, 2578-2580 10.1039/B702882B
- [3] An insight into the origin of room-temperature ferromagnetism in SnO2 and Mn-doped SnO2 quantum dots: an experimental and DFT approach? Dhamodaran Manikandan,S. Amirthapandian,I. S. Zhidkov,A. I. Kukharenko,S. O. Cholakh,Ramaswamy MuruganPhys. Chem. Chem. Phys., 2018,20, 6500-6514 10.1039/C7CP07182E
- [4] An alternative biorefinery approach to address microalgal seasonality: blending with spent coffee grounds Andre Prates Pereira,Tao Dong,Eric P. Knoshaug,Nick Nagle,Ryan Spiller,Bonnie Panczak,Christopher J. Chuck,Philip T. PienkosSustainable Energy Fuels, 2020,4, 3400-3408 10.1039/D0SE00164C
- [5] An algal process treatment combined with the Fenton reaction for high concentrations of amoxicillin and cefradine Haitao Li,Yu Pan,Zhizhi Wang,Shan Chen,Ruixin Guo,Jianqiu ChenRSC Adv., 2015,5, 100775-100782 10.1039/C5RA21508K
- [6] Aggregated-fluorescent detection of PFAS with a simple chip Cheng Fang,Jinjian Wu,Zahra Sobhani,Md. Al Amin,Youhong TangAnal. Methods, 2019,11, 163-170 10.1039/C8AY02382D
- [7] Alternative donor substrates for inverting and retaining glycosyltransferases? Luke L. Lairson,Warren W. WakarchukChem. Commun., 2007, 365-367 10.1039/B614636H
- [8] Acenaphthenic hopanoids, a novel series of aromatised Teresita Carrillo-Hernández,Philippe Schaeffer,Pierre AlbrechtChem. Commun., 2001, 1976-1977 10.1039/B105198A
- [9] An aptasensor for the detection of ampicillin in milk using a personal glucose meter Xixi Li,Nanwei Zhu,Ruohan Li,Qinpu ZhangAnal. Methods, 2020,12, 3376-3381 10.1039/D0AY00256A
- [10] An atomically efficient, highly stable and redox active Ce0.5Tb0.5Ox (3% mol.)/MgO catalyst for total oxidation of methane? Juan J. Sánchez,Miguel López-Haro,Juan C. Hernández-Garrido,Ginesa Blanco,Miguel A. Cauqui,José M. Rodríguez-Izquierdo,José A. Pérez-Omil,José J. Calvino,María P. YesteJ. Mater. Chem. A, 2019,7, 8993-9003 10.1039/C8TA11672E
Journal Name:ANALYSTANALYST
research_products
-
CAS no.: 89640-58-4