Contact lenses for continuous corneal temperature monitoring?
RSC Advances Pub Date: 2019-04-11 DOI: 10.1039/C9RA00601J
Abstract
Temperature variation is a ubiquitous medical sign to monitor ocular conditions including dry eye disease (DED), glaucoma, carotid artery stenosis, diabetic retinopathy, and vascular neuritis. The ability to measure OST in real time is desirable in point-of-care diagnostics. Here, we developed minimally invasive contact lens temperature sensors for continuous monitoring of the corneal temperature. The contact lens sensor consisted of a laser patterned commercial contact lens embedding temperature-sensitive Cholesteric Liquid Crystals (CLCs), which exhibited a fully reversible temperature-dependent color change in the visible spectrum. The contact lens allowed the corneal temperature to be mapped in four key areas, at distances of 0.0, 1.0, 3.0, and 5.0?mm from the pupil's edge. Liquid crystals exhibited a wavelength shift from 738 ± 4 nm to 474 ± 4 nm upon increasing the temperature from 29.0 °C to 40.0 °C, with a time responsivity of 490 ms and a negligible hysteresis. Readouts were performed using a smartphone, which output RGB triplets associated to temperature values. Contact lens sensors based on CLCs were fitted and tested on an ex vivo porcine eye and readouts were compared with infrared thermal measurements, resulting in an average difference of 0.3 °C.
Recommended Literature
- [1] An assay for the enzyme N-acetyl-β-d-glucosaminidase (NAGase) based on electrochemical detection using screen-printed carbon electrodes (SPCEs) R. M. Pemberton,J. P. Hart,T. T. MottramAnalyst, 2001,126, 1866-1871 10.1039/B104874K
- [2] Aluminium complexes with thio-phosphorus ligands: syntheses and characterisations of [Al2(CyPS3)2(CyPHS2)2] and [Al(S2PPh2)3]? Robert P. Davies,Maria A. Giménez,Laura Patel,Andrew J. P. WhiteDalton Trans., 2008, 5705-5707 10.1039/B813427H
- [3] Acetylcholinesterase amperometric detection system based on a cobalt(II) tetraphenylporphyrin-modified electrode Analyst, 1996,121, 1123-1126 10.1039/AN9962101123
- [4] An apparatus for testing water by measurement of its electrical conductivity Analyst, 1912,37, 538-543 10.1039/AN9123700538
- [5] An investigation into the origin of variations in photovoltaic performance using D–D–π–A and D–A–π–A triphenylimidazole dyes with a copper electrolyte? Govind ReddyMol. Syst. Des. Eng., 2021,6, 779-789 10.1039/D1ME00073J
- [6] An autonomous self-optimizing flow machine for the synthesis of pyridine–oxazoline (PyOX) ligands? Eric Wimmer,Daniel Cortés-Borda,Solène Brochard,Elvina Barré,Charlotte Truchet,Fran?ois-Xavier FelpinReact. Chem. Eng., 2019,4, 1608-1615 10.1039/C9RE00096H
- [7] An alkynylboronatecycloaddition strategy to functionalised benzyne derivatives? James D. Kirkham,Patrick M. Delaney,George J. Ellames,Eleanor C. Row,Joseph P. A. HarrityChem. Commun., 2010,46, 5154-5156 10.1039/C0CC01345E
- [8] An integrated chip for immunofluorescence and its application to analyze lysosomal storage disorders Jie Shen,Ying Zhou,Tu Lu,Junya Peng,Zhixiang Lin,Yuhong Pang,Li YuLab Chip, 2012,12, 317-324 10.1039/C1LC20845D
- [9] An atomic scale study of defects in Co2FeAl Ravi Kumar Yadav,R. GovindarajPhys. Chem. Chem. Phys., 2020,22, 26876-26886 10.1039/D0CP04572A
- [10] An artificial photosynthesis system comprising a covalent triazine framework as an electron relay facilitator for photochemical carbon dioxide reduction? Siquan Zhang,Shengyao Wang,Liping Guo,Hao Chen,Bien Tan,Shangbin JinJ. Mater. Chem. C, 2020,8, 192-200 10.1039/C9TC05297F
Journal Name:RSC Advances
research_products
-
CAS no.: 89640-58-4