Determination of free hydrogen cyanide in river water by a solvent-extraction method
ANALYSTANALYST Pub Date: DOI: 10.1039/AN9699400284
Abstract
The method described for the determination of undissociated hydrogen cyanide in river waters is designed to avoid disturbance of the equilibria between hydrogen cyanide, cyanide ion and complex cyanides during the determination. A small proportion of the hydrogen cyanide present is extracted by equilibrating the sample with 1,1,1-trichloroethane. The extracted hydrogen cyanide is then transferred into sodium pyrophosphate solution, and the determination is completed colorimetrically by a modification of the method of Bark and Higson. The effect of temperature on the extraction has been studied. Extractions can be carried out in the field, and conditions have been established for bringing extracted samples back to the laboratory for colorimetric analysis. The method can be used in the range 0 to 2 mg of hydrogen cyanide l–1 and less than 0·01 mg l–1 is detectable. Satisfactory tests have been carried out on solutions of known hydrogen cyanide content, on solutions of metallic complex cyanides and on river waters containing added cyanide.
Recommended Literature
- [1] An asymmetric supercapacitor based on controllable WO3 nanorod bundle and alfalfa-derived porous carbon? Kanjun Sun,Fengting Hua,Shuzhen Cui,Yanrong Zhu,Hui Peng,Guofu MaRSC Adv., 2021,11, 37631-37642 10.1039/D1RA04788D
- [2] An all-solid-state asymmetric device based on a polyaniline hydrogel for a high energy flexible supercapacitor? Hamid Heydari,Mohammad B. GholivandNew J. Chem., 2017,41, 237-244 10.1039/C6NJ02266A
- [3] An investigation of new infrared nonlinear optical material: BaCdSnSe4, and three new related centrosymmetric compounds: Ba2SnSe4, Mg2GeSe4, and Ba2Ge2S6? Kui Wu,Zhihua Yang,Shilie PanDalton Trans., 2015,44, 19856-19864 10.1039/C5DT03215F
- [4] Aggregation-induced emission leading to two distinct emissive species in the solid-state structure of high-dipole organic chromophores? Felix Witte,Philipp Rietsch,Nithiya Nirmalananthan-Budau,Florian Weigert,Jan P. G?tze,Ute Resch-Genger,Siegfried Eigler,Beate PaulusPhys. Chem. Chem. Phys., 2021,23, 17521-17529 10.1039/D1CP02534A
- [5] An approach to asymmetric synthesis of β-aryl alanines by Pd(0)-catalyzed cross-coupling and cyanate-to-isocyanate rearrangement? Piotr Szcze?niak,Sebastian SteckoRSC Adv., 2015,5, 30882-30888 10.1039/C5RA02818C
- [6] An integrated microfluidic 3D tumor system for parallel and high-throughput chemotherapy evaluation? Dan Liu,Rui Hu,Zhongchao Huang,Meilin Sun,Kai HanAnalyst, 2020,145, 6447-6455 10.1039/D0AN01229G
- [7] An autonomous self-optimizing flow machine for the synthesis of pyridine–oxazoline (PyOX) ligands? Eric Wimmer,Daniel Cortés-Borda,Solène Brochard,Elvina Barré,Charlotte Truchet,Fran?ois-Xavier FelpinReact. Chem. Eng., 2019,4, 1608-1615 10.1039/C9RE00096H
- [8] An arsenic trioxide nanoparticle prodrug (ATONP) potentiates a therapeutic effect on an aggressive hepatocellular carcinoma model via enhancement of intratumoral arsenic accumulation and disturbance of the tumor microenvironment? Xin Fu,Qing-rong Liang,Rong-guang Luo,Yan-shu Li,Xiao-ping Xiao,Lu-lu Yu,Wen-zhe Shan,Guang-qin FanJ. Mater. Chem. B, 2019,7, 3088-3099 10.1039/C9TB00349E
- [9] An integrated digital microfluidic chip for multiplexed proteomic sample preparation and analysis by MALDI-MS? Hyejin Moon,Aaron R. Wheeler,Robin L. Garrell,Chang-Jin “CJ” KimLab Chip, 2006,6, 1213-1219 10.1039/B601954D
- [10] Alternative mixtures to R-600a. Theoretical assessment and experimental energy evaluation of binary mixtures in a commercial cooler: Mélanges alternatifs au R-600a. évaluation théorique et évaluation énergétique expérimentale de mélanges binaires dans un refroidisseur commercial. DanielCalleja-Anta,DanielSánchez,LauraNebot-Andres,RamónCabello,RodrigoLlopis 10.1016/j.ijrefrig.2023.05.009
Journal Name:ANALYSTANALYST
research_products
-
CAS no.: 89640-58-4