Chromium(III)-selective electrode based on a macrocyclic compound
Analyst Pub Date: DOI: 10.1039/A901162E
Abstract
A poly(vinyl chloride)-based membrane of 3,10-c-meso-3,5,7,7,10,12,14,14-octamethyl-1,4,8,11- tetraazacyclotetradecane diperchlorate with sodium tetraphenyl borate (STB) as an anion excluder and dibutyl phthalate (DBP), dibutyl butylphosphonate (DBBP), tris(2-ethylhexyl) phosphate (TEP) and tributyl phosphate (TBP) as plasticizing solvent mediators was prepared and investigated as a Cr(III)-selective electrode. The best performance was observed with the membrane having the ligand–PVC–DBP–STB composition 2:10:7:1, which worked well over a wide concentration range (1.77 × 10–6–0.1 mol L–1) with a Nernstian slope of 20 mV per decade of activity between pH 3.0 and 6.5. This electrode showed a fast response time of 15 s and was used over a period of 4 months with good reproducibility (s = 0.4 mV). The selectivity coefficients for mono-, di- and trivalent cations indicate excellent selectivity for Cr(III) ions over a large number of cations. Anions such as Cl– and SO42– do not interfere and the electrode also works satisfactorily in a partially non-aqueous medium. The sensor has been used as an indicator electrode in the potentiometric titration of Cr(III) with EDTA. The practical utility of the membrane sensor has also been observed in solutions contaminated with detergents i.e., cetyltrimethylammonium bromide and sodium dodecyl sulfate. Above all, the membrane sensor has been used very successfully to analyse some food materials for the determination of Cr(III) ion.
Recommended Literature
- [1] Exchanged ligands on the surface of a giant cluster: [(MoO3)176(H2O)63(CH3OH)17Hn](32 – n)– Chem. Commun., 1998, 1501-1502 10.1039/A801804I
- [2] Excess electrons in lithium–ethylamine solutions—density, electrical conductivity and EPR studies Phys. Chem. Chem. Phys., 1999,1, 3561-3565 10.1039/A900683D
- [3] Emergence of microfluidic wearable technologies Joo Chuan Yeo,KenryLab Chip, 2016,16, 4082-4090 10.1039/C6LC00926C
- [4] Evidence of field induced slow magnetic relaxation in cis-[Co(hfac)2(H2O)2] exhibiting tri-axial anisotropy with a negative axial component? Denis V. Korchagin,Elena A. Yureva,Alexander V. Akimov,Eugenii Ya. Misochko,Gennady V. Shilov,Artem D. Talantsev,Roman B. Morgunov,Alexander A. Shakin,Sergey M. Aldoshin,Boris S. TsukerblatDalton Trans., 2017,46, 7540-7548 10.1039/C7DT01236E
- [5] Distinct impact of glycation towards the aggregation and toxicity of murine and human amyloid-β? Eunju Nam,Jiyeon Han,Sunhee Choi,Mi Hee LimChem. Commun., 2021,57, 7637-7640 10.1039/D1CC02695J
- [6] Enabling high-throughput single-animal gene-expression studies with molecular and micro-scale technologies Jason WanLab Chip, 2020,20, 4528-4538 10.1039/D0LC00881H
- [7] Fe(ii)-Assisted one-pot synthesis of ultra-small core–shell Au–Pt nanoparticles as superior catalysts towards the HER and ORR? Yi Cao,Yujiao Xiahou,Lixiang Xing,Xiang Zhang,Hong Li,ChenShou Wu,Haibing XiaNanoscale, 2020,12, 20456-20466 10.1039/D0NR04995F
- [8] Fe(iii)-mediated isomerization of α,α-diarylallylic alcohols to ketones via radical 1,2-aryl migration? Ziyang Deng,Changwei Chen,Sunliang CuiRSC Adv., 2016,6, 93753-93755 10.1039/C6RA20007A
- [9] Evidence for the intrinsic nature of band-gap states electrochemically observed on atomically flat TiO2(110) surfaces? Shintaro Takata,Yoshihiro MiuraPhys. Chem. Chem. Phys., 2014,16, 24784-24789 10.1039/C4CP03280B
- [10] Establishing empirical design rules of nucleic acid templates for the synthesis of silver nanoclusters with tunable photoluminescence and functionalities towards targeted bioimaging applications? Jason Y. C. Lim,Yong Yu,Guorui Jin,Kai Li,Yi Lu,Jianping XieNanoscale Adv., 2020,2, 3921-3932 10.1039/D0NA00381F
Journal Name:Analyst
research_products
-
CAS no.: 89640-58-4