Biomolecular analysis and cancer diagnostics by negative mode probe electrospray ionization?
Analyst Pub Date: 2013-01-10 DOI: 10.1039/C3AN36554A
Abstract
We have examined several combinations of solvents and probes with the aim of optimizing the ionization conditions for biomolecules e.g., proteins, peptides and lipids by negative mode probe electrospray ionization mass spectrometry (PESI-MS). With the data presented in this study, negative-mode PESI-MS can be considered as a potential tool for biomolecular analysis and cancer diagnostics because of its simplicity in instrumental configuration. A sharper sampling probe was found to be better for obtaining high quality mass spectra because it can generate stable electrospray without the occurrence of gas breakdown. Although the best conditions may depend on each sample, aqueous organic solvent solutions, especially isopropanol–H2O (1/1) with a pH of ≥7, are shown to be preferable for negative-mode PESI-MS, which was successfully applied to colon cancer diagnosis.
Recommended Literature
- [1] Estimating and correcting interference fringes in infrared spectra in infrared hyperspectral imaging Ghazal Azarfar,Ebrahim Aboualizadeh,Nicholas M. Walter,Simona Ratti,Camilla Olivieri,Alessandra Norici,Michael Nasse,Achim Kohler,Mario GiordanoAnalyst, 2018,143, 4674-4683 10.1039/C8AN00093J
- [2] Evidence of pre-micellar aggregates in aqueous solution of amphiphilic PDMS–PEO block copolymer? Domenico Lombardo,Gianmarco Munaò,Pietro Calandra,Luigi Pasqua,Maria Teresa CaccamoPhys. Chem. Chem. Phys., 2019,21, 11983-11991 10.1039/C9CP02195G
- [3] Exceptionally high temperature spin crossover in amide-functionalised 2,6-bis(pyrazol-1-yl)pyridine iron(ii) complex revealed by variable temperature Raman spectroscopy and single crystal X-ray diffraction? Max Attwood,Hiroki Akutsu,Lee Martin,Toby J. Blundell,Pierre Le Maguere,Scott S. TurnerDalton Trans., 2021,50, 11843-11851 10.1039/D1DT01743H
- [4] Estimation of hydrogen sulfide from crude petroleum: a unique invention using a simple chemosensor? Shampa Kundu,Prithidipa SahooNew J. Chem., 2019,43, 12369-12374 10.1039/C9NJ02628B
- [5] Elusive 2-aminofuran Diels–Alder substrates for a straightforward synthesis of polysubstituted anilines? Ana G. Neo,Ana Bornadiego,Jesús Díaz,Stefano Marcaccini,Carlos F. MarcosOrg. Biomol. Chem., 2013,11, 6546-6555 10.1039/C3OB41411F
- [6] Excellent energy storage performance in NaNbO3-based relaxor antiferroeic ceramics under a low electric field XuxinCheng,XiaomingChen,PengyuanFan 10.1007/s10832-022-00283-w
- [7] Excitable dynamics in the bromate–sulfite–ferrocyanide reaction J. Zagora,M. Vosla?,L. Schreiberová,I. SchreiberPhys. Chem. Chem. Phys., 2002,4, 1284-1291 10.1039/B110048C
- [8] Distribution and ecological risk assessment of typical antibiotics in the surface waters of seven major rivers, China? Environ. Sci.: Processes Impacts, 2021,23, 1088-1100 10.1039/D1EM00079A
- [9] Excellent electrochemical performance of LiFe0.4Mn0.6PO4 microspheres produced using a double carbon coating process? Yong Ping Huang,Tao Tao,Zheng Chen,Wei Han,Ying Wu,Chunjiang Kuang,Shaoxiong Zhou,Ying ChenJ. Mater. Chem. A, 2014,2, 18831-18837 10.1039/C4TA03994G
- [10] Examination of the hydrogen-bonding networks in small water clusters (n = 2–5, 13, 17) using absolutely localized molecular orbital energy decomposition analysis? Erika A. Cobar,Paul R. Horn,Robert G. Bergman,Martin Head-GordonPhys. Chem. Chem. Phys., 2012,14, 15328-15339 10.1039/C2CP42522J
Journal Name:Analyst
research_products
-
CAS no.: 89640-58-4