Application of a sensitive liquid chromatography-mass spectrometry method to a pharmacokinetic study of nerolidol in rat plasma
Analytical Methods Pub Date: 2015-12-09 DOI: 10.1039/C5AY02575C
Abstract
Nerolidol is a dominant volatile compound isolated from Oplopanax horridus. A liquid chromatography-electrospray ionization-mass spectrometry (LC-MS) method was used to evaluate the pharmacokinetics of nerolidol in rats. A series of extraction and concentration methods were optimized for the extraction efficiency of biosamples. Chromatographic separation was performed on a reverse LC column within a total run time of 14.5 min. This method was linear over 10–10?000 ng mL?1 and the limit of quantification for nerolidol was 10 ng mL?1, with both inter-day and intra-day (CV) precision < 8% and accuracy (RE) ranging from ?6% to 6%. RE for nerolidol nerolidol was lower than 11% after 4 h and 16% after 27 h freeze–thaw cycles, indicating the samples were stable in the analysis conditions.
Recommended Literature
- [1] An approach to asymmetric synthesis of β-aryl alanines by Pd(0)-catalyzed cross-coupling and cyanate-to-isocyanate rearrangement? Piotr Szcze?niak,Sebastian SteckoRSC Adv., 2015,5, 30882-30888 10.1039/C5RA02818C
- [2] Acetyl group orientation modulates the electronic ground-state asymmetry of the special pair in purple bacterial reaction centers P. K. Wawrzyniak,M. T. P. Beerepoot,H. J. M. de Groot,F. BudaPhys. Chem. Chem. Phys., 2011,13, 10270-10279 10.1039/C1CP20213H
- [3] An artificial CO-releasing metalloprotein built by histidine-selective metallation? Inês S. Albuquerque,Hélia F. Jeremias,Miguel Chaves-Ferreira,Dijana Matak-Vinkovic,Omar Boutureira,Carlos C. Rom?oChem. Commun., 2015,51, 3993-3996 10.1039/C4CC10204E
- [4] Acetyl protected thiol methacrylic polymers as effective ligands to keep quantum dots in luminescent standby mode? Marta Liras,Isabel Quijada-Garrido,Marta Palacios-Cuesta,Sonia Mu?oz-Durieux,Olga GarcíaPolym. Chem., 2014,5, 433-442 10.1039/C3PY00987D
- [5] An artificial enzyme cascade amplification strategy for highly sensitive and specific detection of breast cancer-derived exosomes? Huiying Xu,Lu Zheng,Yu Zhou,Bang-Ce YeAnalyst, 2021,146, 5542-5549 10.1039/D1AN01071A
- [6] An investigation of the electrochemical delithiation process of carbon coated α-Fe2O3nanoparticles Adrian Brandt,Florian Winter,Sebastian Klamor,Frank Berkemeier,Jatinkumar Rana,Rainer P?ttgen,Andrea BalducciJ. Mater. Chem. A, 2013,1, 11229-11236 10.1039/C3TA11821E
- [7] An anti-leakage liquid metal thermal interface material Kaiyuan Huang,Wangkang Qiu,Meilian Ou,Xiaorui Liu,Zenan Liao,Sheng ChuRSC Adv., 2020,10, 18824-18829 10.1039/D0RA02351E
- [8] An analyte-triggered artificial peroxidase system based on dimanganese complex for a versatile enzyme assay? Suji Lee,Min Su HanChem. Commun., 2021,57, 9450-9453 10.1039/D1CC03638F
- [9] Aggregation of biologically important peptides and proteins: inhibition or acceleration depending on protein and metal ion concentrations Benjamin Gabriel Poulson,Kacper Szczepski,Joanna Izabela Lachowicz,Lukasz Jaremko,Abdul-Hamid Emwas,Mariusz JaremkoRSC Adv., 2020,10, 215-227 10.1039/C9RA09350H
- [10] Alumina grafted SBA-15 sustainable bifunctional catalysts for direct cross-coupling of benzylic alcohols to diarylmethanes? Chandran Rajendran,Govindaswamy Satishkumar,Charlotte Lang,Eric M. GaigneauxCatal. Sci. Technol., 2020,10, 2583-2592 10.1039/D0CY00471E
Journal Name:Analytical Methods
research_products
-
CAS no.: 89640-58-4