Sample pre-treatment techniques for use with ICP-MS hyphenated techniques for elemental speciation in biological samples
Journal of Analytical Atomic Spectrometry Pub Date: 2016-08-11 DOI: 10.1039/C6JA00077K
Abstract
The biochemical reactions involving trace elements depend on the nature and form of their chemical species in a biological system. Consequently, the study of the chemical speciation of a given element in biological samples has become essential for understanding their bioavailability and toxicity. Inductively coupled plasma-mass spectrometry (ICP-MS) hyphenated techniques are the most powerful and widely used for elemental speciation combining both high sensitivity and good selectivity for the determination of ultra-trace elements in biological samples. However, direct analysis of biological samples can suffer from matrix interferences, and both the low concentrations of chemical species, and in some cases, the limited amount of sample available can present analytical challenges. Therefore, there is a need to develop sample pre-treatment methods that can be used to remove the matrix and pre-concentrate the species of interest prior to analysis. This review will focus specifically on the state-of-the-art sample pre-treatment methods published in the last ten years including liquid and solid phase micro-extraction, and chip-based manifolds that can be coupled to ICP-MS hyphenated techniques. The different methods are evaluated for their ability to be deployed for the pre-treatment of actual biological samples. The development trends in this area of research are discussed, and integrated automated miniaturized systems are also reviewed.
Recommended Literature
- [1] Exceptionally high temperature spin crossover in amide-functionalised 2,6-bis(pyrazol-1-yl)pyridine iron(ii) complex revealed by variable temperature Raman spectroscopy and single crystal X-ray diffraction? Max Attwood,Hiroki Akutsu,Lee Martin,Toby J. Blundell,Pierre Le Maguere,Scott S. TurnerDalton Trans., 2021,50, 11843-11851 10.1039/D1DT01743H
- [2] Emergence of cationic polyamine dendrimersomes: design, stimuli sensitivity and potential biomedical applications Partha Laskar,Christine DufèsNanoscale Adv., 2021,3, 6007-6026 10.1039/D1NA00536G
- [3] EWOD-driven droplet microfluidic device integrated with optoelectronic tweezers as an automated platform for cellular isolation and analysis? Gaurav J. Shah,Eric P.-Y. Chiou,Ming C. Wu,Chang-Jin “CJ” KimLab Chip, 2009,9, 1732-1739 10.1039/B821508A
- [4] Evidence that the availability of an allylic hydrogen governs the regioselectivity of the Wacker oxidation Matthew J. Gaunt,Jinquan Yu,Jonathan B. SpencerChem. Commun., 2001, 1844-1845 10.1039/B103066N
- [5] Excellent peroxidase mimicking property of CuO/Pt nanocomposites and their application as an ascorbic acid sensor? Xinhuan Wang,Shuangfei Cai,Cui QiAnalyst, 2017,142, 2500-2506 10.1039/C7AN00589J
- [6] Emerging enantiomeric resolution materials with homochiral nano-fabrications Ji-Ping WeiNanoscale, 2015,7, 11815-11832 10.1039/C5NR03048J
- [7] Fe/Fe3C@C nanoparticles encapsulated in N-doped graphene–CNTs framework as an efficient bifunctional oxygen electrocatalyst for robust rechargeable Zn–air batteries? Zhiyan Chen,Nan Wu,Yaobing Wang,Bing Wang,Yingde WangJ. Mater. Chem. A, 2018,6, 516-526 10.1039/C7TA08423D
- [8] Emerging 2D hybrid nanomaterials: towards enhanced sensitive and selective conductometric gas sensors at room temperature Hanie Hashtroudi,Ian D. R. MackinnonJ. Mater. Chem. C, 2020,8, 13108-13126 10.1039/D0TC01968B
- [9] Evolved polymerases facilitate selection of fully 2′-OMe-modified aptamers? Zhixia Liu,Tingjian Chen,Floyd E. RomesbergChem. Sci., 2017,8, 8179-8182 10.1039/C7SC03747C
- [10] Excimer–monomer switch: a reaction-based approach for selective detection of fluoride? Qiao Song,Angela Bamesberger,Lingyun Yang,Haley Houtwed,Haishi CaoAnalyst, 2014,139, 3588-3592 10.1039/C4AN00522H
Journal Name:Journal of Analytical Atomic Spectrometry
research_products
-
CAS no.: 89640-58-4