Simultaneous analysis of acylcarnitines using MALDI-TOF mass spectrometry based on a parylene matrix chip?
Analyst Pub Date: 2022-09-23 DOI: 10.1039/D2AN01199A
Abstract
Short and medium chain acylcarnitines have been used for the diagnosis of various fatty acid oxidation and organic acid disorders. This report presents a multiplex and quantitative analysis of acylcarnitines using MALDI-TOF MS based on a parylene matrix chip. The parylene matrix chip was fabricated by the deposition of a nanoporous film of parylene on an organic matrix array, which reduced the number of mass peaks from the organic matrix in the low m/z range. Quantitative analysis was possible using the parylene matrix chip because of the formation of nano-sized sample crystals on the nanoporous parylene film. Seven acylcarnitines were quantitatively analyzed using the chip; the method detection range included the cut-off values for metabolic disorders. The seven acylcarnitines of different concentrations were simultaneously detected using the parylene matrix chip and the interference from the mixed carnitines was estimated. Real L-carnitine (C0) samples were analyzed using serial dilution, and the recoveries were calculated by comparisons with a standard curve.
Recommended Literature
- [1] An artificial enzyme cascade amplification strategy for highly sensitive and specific detection of breast cancer-derived exosomes? Huiying Xu,Lu Zheng,Yu Zhou,Bang-Ce YeAnalyst, 2021,146, 5542-5549 10.1039/D1AN01071A
- [2] Aggregation of biologically important peptides and proteins: inhibition or acceleration depending on protein and metal ion concentrations Benjamin Gabriel Poulson,Kacper Szczepski,Joanna Izabela Lachowicz,Lukasz Jaremko,Abdul-Hamid Emwas,Mariusz JaremkoRSC Adv., 2020,10, 215-227 10.1039/C9RA09350H
- [3] An all-solid-state asymmetric device based on a polyaniline hydrogel for a high energy flexible supercapacitor? Hamid Heydari,Mohammad B. GholivandNew J. Chem., 2017,41, 237-244 10.1039/C6NJ02266A
- [4] Acetyl protected thiol methacrylic polymers as effective ligands to keep quantum dots in luminescent standby mode? Marta Liras,Isabel Quijada-Garrido,Marta Palacios-Cuesta,Sonia Mu?oz-Durieux,Olga GarcíaPolym. Chem., 2014,5, 433-442 10.1039/C3PY00987D
- [5] Alt-proteins: A promising future 10.1002/fsat.3701_10.x
- [6] An inter-tangled network of redox-active and conducting polymers as a cathode for ultrafast rechargeable batteries Jieun Kim,Han-Saem Park,Tae-Hee Kim,Sung Yeol Kim,Hyun-Kon SongPhys. Chem. Chem. Phys., 2014,16, 5295-5300 10.1039/C3CP54624A
- [7] An apparatus for testing water by measurement of its electrical conductivity Analyst, 1912,37, 538-543 10.1039/AN9123700538
- [8] An asymmetric supercapacitor based on controllable WO3 nanorod bundle and alfalfa-derived porous carbon? Kanjun Sun,Fengting Hua,Shuzhen Cui,Yanrong Zhu,Hui Peng,Guofu MaRSC Adv., 2021,11, 37631-37642 10.1039/D1RA04788D
- [9] An integrated system for field analysis of Cd(ii) and Pb(ii) via preconcentration using nano-TiO2/cellulose paper composite and subsequent detection with a portable X-ray fluorescence spectrometer? Xiaofeng LinRSC Adv., 2016,6, 9002-9006 10.1039/C5RA25693C
- [10] An artificial photosynthetic system for photoaccumulation of two electrons on a fused dipyridophenazine (dppz)–pyridoquinolinone ligand? Philipp Traber,Stephan Kupfer,Stefanie Gr?fe,Isabelle Baussanne,Martine Demeunynck,Jean-Marie Mouesca,Serge Gambarelli,Vincent Artero,Murielle Chavarot-KerlidouChem. Sci., 2018,9, 4152-4159 10.1039/C7SC04348A
Journal Name:Analyst
research_products
-
CAS no.: 89640-58-4