Analysis of nucleosides and nucleobases by microemulsion electrokinetic capillary chromatography coupled with field-amplified sample injection?
Analytical Methods Pub Date: 2015-01-07 DOI: 10.1039/C4AY01796J
Abstract
A microemulsion electrokinetic capillary (MEEKC) chromatography method was online-coupled with field-amplified sample injection (FASI) for the analysis of nucleosides and nucleobases, namely cytidine, guanosine, N6-methyladenosine, fluorouracil, thymine, adenine, mercaptopurine, 6-hydroxypurine, and guanine. A microemulsion background electrolyte containing 10 mM sodium dodecyl sulfate (SDS), 0.6% (v/v) 1-butanol, 0.5% (v/v) ethyl acetate and 98.9% (v/v) borate buffer (10 mM; pH 9.0) was used as the running buffer. An online field-amplified sample injection (FASI) technique was adopted to improve the detection sensitivity. Baseline separation of nine nucleosides was achieved within 12 min with detection limits (S/N = 3) between 0.22 and 2.97 μg mL?1 with the DAD detector at 200 nm under optimized conditions. The proposed method was applied to the determination of nine nucleoside compounds in spiked urine and serum samples with the recoveries ranging 91.2–113% and 85.2–112% and the relative standard deviations (RSDs, n = 3) at less than 5.90% and 8.22%, respectively.
Recommended Literature
- [1] Dissociation of large gaseous serine clusters produces abundant protonated serine octamer Jacob S. Jordan,Evan R. WilliamsAnalyst, 2021,146, 2617-2625 10.1039/D1AN00273B
- [2] Evidence of CO2 molecule acting as an electron acceptor on a nanoporous metal–organic-framework MIL-53 or Cr3+(OH)(O2C–C6H4–CO2)? Alexandre Vimont,Arnaud Travert,Philippe Bazin,Jean-Claude Lavalley,Marco Daturi,Christian Serre,Gérard Férey,Sandrine Bourrelly,Philip L. LlewellynChem. Commun., 2007, 3291-3293 10.1039/B703468G
- [3] Emergence of microfluidic wearable technologies Joo Chuan Yeo,KenryLab Chip, 2016,16, 4082-4090 10.1039/C6LC00926C
- [4] Exchanged ligands on the surface of a giant cluster: [(MoO3)176(H2O)63(CH3OH)17Hn](32 – n)– Chem. Commun., 1998, 1501-1502 10.1039/A801804I
- [5] Dissolved oxygen sensor based on fluorescence quenching of oxygen-sensitive ruthenium complexes immobilized in sol–gel-derived porous silica coatings Analyst, 1996,121, 785-788 10.1039/AN9962100785
- [6] Fe3O4/FeS2 heterostructures enable efficient oxygen evolution reaction? Xingqun Zheng,Lele Song,Xin Feng,Li Li,Zidong WeiJ. Mater. Chem. A, 2020,8, 14145-14151 10.1039/C9TA13775K
- [7] Distinct correlation between (CN2)x units and pores: a low-cost method for predesigned wide range control of micropore size of porous carbon? Xiaotong Feng,Lei Bian,Jie Ma,Lei Zhou,Xiayan Wang,Guangsheng Guo,Qiaosheng PuChem. Commun., 2019,55, 3963-3966 10.1039/C9CC01213C
- [8] Excellent electrochemical performance of LiFe0.4Mn0.6PO4 microspheres produced using a double carbon coating process? Yong Ping Huang,Tao Tao,Zheng Chen,Wei Han,Ying Wu,Chunjiang Kuang,Shaoxiong Zhou,Ying ChenJ. Mater. Chem. A, 2014,2, 18831-18837 10.1039/C4TA03994G
- [9] Evolution of shape, size, and areal density of a single plane of Si nanocrystals embedded in SiO2 matrix studied by atom probe tomography Bin Han,Yasuo Shimizu,Gabriele Seguini,Celia Castro,Gérard Ben Assayag,Koji Inoue,Yasuyoshi Nagai,Sylvie Schamm-Chardon,Michele PeregoRSC Adv., 2016,6, 3617-3622 10.1039/C5RA26710B
- [10] Establishment and implications of a characterization method for magnetic nanoparticle using cell tracking velocimetry and magnetic susceptibility modified solutions Huading Zhang,Lee R. Moore,Maciej Zborowski,P. Stephen Williams,Shlomo Margel,Jeffrey J. ChalmersAnalyst, 2005,130, 514-527 10.1039/B412723D
Journal Name:Analytical Methods
research_products
-
CAS no.: 89640-58-4