The application of isotopically labeled analogues for the determination of small organic compounds by GC/MS with selected ion monitoring?
Analytical MethodsANAL METHODS-UK Pub Date: 2020-07-23 DOI: 10.1039/D0AY00723D
Abstract
The study aimed to show the limitations and advantages of the use of stable isotope labeled internal standards (SILISs) for the quantification of small polar compounds (ibuprofen, diclofenac, metoprolol, bisphenol A, 17β-estradiol) in water samples by GC/MS with selected ion monitoring (SIM). The selection of SIM ions shows that for some of the analytes, in the form of trimethylsilylated derivatives, it is problematic to have a minimum of two qualifiers because of the poor mass spectra, high impact of the background or overlapping of the peaks from the analytes and SILISs. The “isotope effect” was observed on GC chromatograms. During the development of the SIM method, special attention was given to the qualifier/quantifier ratio, for which a variety of acceptance criteria can be found in the official guidelines. The values of the solid-phase extraction efficiency, as well as the matrix effect and absolute recovery were the same for the analytes and their corresponding SILISs. The developed method was used for the quantification of analytes in wastewaters.
Recommended Literature
- [1] Fate of single walled carbon nanotubes in wetland ecosystems? Joseph H. Bisesi,Tara Sabo-AttwoodEnviron. Sci.: Nano, 2014,1, 574-583 10.1039/C4EN00063C
- [2] Excimer emission and magnetoluminescence of radical-based zinc(ii) complexes doped in host crystals? Shojiro Kimura,Tetsuro KusamotoChem. Commun., 2020,56, 11195-11198 10.1039/D0CC04830E
- [3] Dissociative dynamics of O2 on Ag(110)? Ivor Lon?ari?Phys. Chem. Chem. Phys., 2015,17, 9436-9445 10.1039/C4CP05900J
- [4] Fast synthesis of red Li3BaSrLn3(WO4)8:Eu3+ phosphors for white LEDs under near-UV excitation by a microwave-assisted solid state reaction method and photoluminescence studies Bo Wei,Zhenyu Liu,Chen Xie,Shu Yang,Wentao Tang,Aiwei Gu,Wing-Tak Wong,Ka-Leung WongJ. Mater. Chem. C, 2015,3, 12322-12327 10.1039/C5TC03165F
- [5] Dissociation of large gaseous serine clusters produces abundant protonated serine octamer Jacob S. Jordan,Evan R. WilliamsAnalyst, 2021,146, 2617-2625 10.1039/D1AN00273B
- [6] Estimates of hydride ion stability in condensed systems: energy of formation and solvation in aqueous and polar-organic solvents Craig A. Kelly,David R. RosseinskyPhys. Chem. Chem. Phys., 2001,3, 2086-2090 10.1039/B010092G
- [7] Distinct correlation between (CN2)x units and pores: a low-cost method for predesigned wide range control of micropore size of porous carbon? Xiaotong Feng,Lei Bian,Jie Ma,Lei Zhou,Xiayan Wang,Guangsheng Guo,Qiaosheng PuChem. Commun., 2019,55, 3963-3966 10.1039/C9CC01213C
- [8] Emergence of cationic polyamine dendrimersomes: design, stimuli sensitivity and potential biomedical applications Partha Laskar,Christine DufèsNanoscale Adv., 2021,3, 6007-6026 10.1039/D1NA00536G
- [9] EWOD-driven droplet microfluidic device integrated with optoelectronic tweezers as an automated platform for cellular isolation and analysis? Gaurav J. Shah,Eric P.-Y. Chiou,Ming C. Wu,Chang-Jin “CJ” KimLab Chip, 2009,9, 1732-1739 10.1039/B821508A
- [10] Evolution of dealloying induced strain in nanoporous gold crystals? Ross Harder,David C. Dunand,Ian McNultyNanoscale, 2017,9, 5686-5693 10.1039/C6NR09635B
Journal Name:Analytical MethodsANAL METHODS-UK
research_products
-
CAS no.: 89640-58-4