An automated method for the determination of lead in calcareous materials utilising liquid ion exchange
ANALYSTANALYST Pub Date: DOI: 10.1039/AN9729700823
Abstract
An automated method for the determination of lead in calcium carbonate, lime and limestone with the Technicon AutoAnalyzer is described. The method is based on the extraction of lead from an acidic chloride solution of the sample with a long-chain amine liquid ion exchanger, followed by re-extraction into an ammonia-ammonium citrate buffer at pH 9. Finally, the lead is extracted as the lead-dithizone complex into chloroform and the optical density of the complex measured at 510 nm. The separation of lead prior to formation of the lead-dithizone complex results in low background and blank readings. Lead levels of 0 to 20 p.p.m. can be determined at a rate of twenty samples per hour. Other trace metals which occur in calcareous materials do not interfere.
Recommended Literature
- [1] Emulsifier-free, organotellurium-mediated living radical emulsion polymerization (emulsion TERP) of styrene: poly(dimethylaminoethyl methacrylate) macro-TERP agent? Yukiya KitayamaPolym. Chem., 2014,5, 2784-2792 10.1039/C3PY01539D
- [2] Empowering microfluidics by micro-3D printing and solution-based mineral coating? Hongxia Li,Aikifa Raza,Qiaoyu Ge,Jin-You Lu,TieJun ZhangSoft Matter, 2020,16, 6841-6849 10.1039/D0SM00958J
- [3] Excitation energies from ground-state density-functionals by means of generator coordinates A. B. F. da Silva,K. CapellePhys. Chem. Chem. Phys., 2009,11, 4564-4569 10.1039/B902529D
- [4] Exciplex emission from the mixed dimer of naphthalene and 2-cyanonaphthalene in a supersonic jet Aloke Das,K. K. Mahato,Chayan K. Nandi,Tapas Chakraborty,Shridhar R. Gadre,Nikhil A. GokhalePhys. Chem. Chem. Phys., 2002,4, 2162-2168 10.1039/B200124C
- [5] Evolving better nanoparticles: Genetic algorithms for optimising cluster geometries Dalton Trans., 2003, 4193-4207 10.1039/B305686D
- [6] Dissociative electron attachment to HGaF4 Lewis–Br?nsted superacid Marcin Czapla,Jack SimonsPhys. Chem. Chem. Phys., 2018,20, 21739-21745 10.1039/C8CP04007A
- [7] Evidence of pre-micellar aggregates in aqueous solution of amphiphilic PDMS–PEO block copolymer? Domenico Lombardo,Gianmarco Munaò,Pietro Calandra,Luigi Pasqua,Maria Teresa CaccamoPhys. Chem. Chem. Phys., 2019,21, 11983-11991 10.1039/C9CP02195G
- [8] Emergence of microfluidic wearable technologies Joo Chuan Yeo,KenryLab Chip, 2016,16, 4082-4090 10.1039/C6LC00926C
- [9] Fatty acid eutectic mixtures and derivatives from non-edible animal fat as phase change materials? Pau Gallart-Sirvent,Marc Martín,Gemma Villorbina,Mercè Balcells,Aran Solé,Luisa F. Cabeza,Ramon Canela-GarayoaRSC Adv., 2017,7, 24133-24139 10.1039/C7RA03845C
- [10] Evidence that the availability of an allylic hydrogen governs the regioselectivity of the Wacker oxidation Matthew J. Gaunt,Jinquan Yu,Jonathan B. SpencerChem. Commun., 2001, 1844-1845 10.1039/B103066N
Journal Name:ANALYSTANALYST
research_products
-
CAS no.: 89640-58-4