The quantification of human chorionic gonadotropin by two isotope dilution mass spectrometry methods?
Analytical Methods Pub Date: 2014-08-22 DOI: 10.1039/C4AY01488J
Abstract
Two isotope dilution mass spectrometry (IDMS) methods were established and compared for absolute quantification of the mass fraction of an important clinical diagnostic marker, i.e. human chorionic gonadotropin (hCG), by employing hydrolysis and enzymatic digestion. In the first method, after hydrolysis of the protein, amino acids were separated by high-performance liquid chromatography (HPLC) and then detected by tandem mass spectrometry (MS) with multiple reaction monitoring (MRM) for phenylalanine, proline, valine and the internal standards (13C9-phenylalanine, 13C5-proline and 13C5-valine). In the second method, after enzyme digestion, the signature peptide (VLQGVLPALPQVVCNYR, m/z = 964 → 1036) and the internal standard (d10-VLQGVL*PALPQVVCNYR, m/z = 970 → 1317) were separated by HPLC, and then detected by MS with MRM. By optimizing the key factors of hydrolysis and enzymatic digestion, the mass fractions of hCG detected by these two methods are consistent. The mass fraction of hCG by hydrolysis is 0.6150 g g?1 (expanded uncertainty = 0.016 g g?1, k = 2), the mass fraction of hCG by enzyme digestion is 0.5810 g g?1 (expanded uncertainty = 0.072 g g?1, k = 2), and the weighted average mass fraction is 0.6126 g g?1 (expanded uncertainty = 0.016 g g?1, k = 2). This study would benefit the absolute quantification of clinical marker proteins, and underpin the development of relative certified reference materials of clinical diagnostic markers to ensure the accuracy, comparability and traceability of medical laboratory testing.
Recommended Literature
- [1] Dissolved oxygen sensor based on fluorescence quenching of oxygen-sensitive ruthenium complexes immobilized in sol–gel-derived porous silica coatings Analyst, 1996,121, 785-788 10.1039/AN9962100785
- [2] Establishing plasmon contribution to chemical reactions: alkoxyamines as a thermal probe? Olga Guselnikova,Gérard Audran,Jean-Patrick Joly,Andrii Trelin,Evgeny V. Tretyakov,Vaclav Svorcik,Oleksiy Lyutakov,Sylvain R. A. MarqueChem. Sci., 2021,12, 4154-4161 10.1039/D0SC06470J
- [3] Fast synthesis of copper nanoclusters through the use of hydrogen peroxide additive and their application for the fluorescence detection of Hg2+ in water samples? Liao Xiaoqing,Li Ruiyi,Li Zaijun,Sun Xiulan,Wang Zhouping,Liu JunkangNew J. Chem., 2015,39, 5240-5248 10.1039/C5NJ00831J
- [4] Emulsion technologies for multicellular tumour spheroid radiation assays? Kay S. McMillan,Anthony G. McCluskey,Annette Sorensen,Marie Boyd,Michele ZagnoniAnalyst, 2016,141, 100-110 10.1039/C5AN01382H
- [5] Dissociation of large gaseous serine clusters produces abundant protonated serine octamer Jacob S. Jordan,Evan R. WilliamsAnalyst, 2021,146, 2617-2625 10.1039/D1AN00273B
- [6] Evolutionary de novo design of phenothiazine derivatives for dye-sensitized solar cells? Vishwesh Venkatraman,Marco Foscato,Vidar R. Jensen,Bj?rn K?re AlsbergJ. Mater. Chem. A, 2015,3, 9851-9860 10.1039/C5TA00625B
- [7] Enabling shape memory and healable effects in a conjugated polymer by incorporating siloxane via dynamic imine bond? Yaling Zhang,Chunhui Dai,Shiwei Zhou,Bin LiuChem. Commun., 2018,54, 10092-10095 10.1039/C8CC05410J
- [8] Evidence for the intrinsic nature of band-gap states electrochemically observed on atomically flat TiO2(110) surfaces? Shintaro Takata,Yoshihiro MiuraPhys. Chem. Chem. Phys., 2014,16, 24784-24789 10.1039/C4CP03280B
- [9] EWOD-driven droplet microfluidic device integrated with optoelectronic tweezers as an automated platform for cellular isolation and analysis? Gaurav J. Shah,Eric P.-Y. Chiou,Ming C. Wu,Chang-Jin “CJ” KimLab Chip, 2009,9, 1732-1739 10.1039/B821508A
- [10] Excellent lithium ion storage property of porous MnCo2O4 nanorods? Peiyuan Zeng,Xiaoxiao Wang,Ming Ye,Qiuyang Ma,Jianwen Li,Wanwan Wang,Baoyou Geng,Zhen FangRSC Adv., 2016,6, 23074-23084 10.1039/C5RA26176G
Journal Name:Analytical Methods
research_products
-
CAS no.: 89640-58-4