Systematic oligoaniline-based derivatives: ACQ–AIE conversion with a tunable insertion effect and quantitative fluorescence “turn-on” detection of BSA?
Materials Chemistry Frontiers Pub Date: 2018-12-18 DOI: 10.1039/C8QM00543E
Abstract
The aggregation-induced emission (AIE) phenomenon has attracted persistent attention in recent years. Currently, the molecular design is mainly based on ring-shaped molecules. Hence, a novel strategy was put forward to achieve conversion from aggregation-caused quenching to AIE in derivatives of aniline oligomers using a new “chain-insertion” pattern. Studies of aniline oligomer derivatives indicate a tunable insertion effect on the AIE behaviors of the derivatives. Fully substituted oligoanilines exhibited typical AIE behavior, while partially substituted derivatives were AIE-inactive. In addition, luminescence wavelength and solid fluorescence in aniline derivatives can be effectively regulated by insertion and chain length. The resulting model will contribute to simplified and systematic research into oligomer-based AIEgens. Moreover, fully substituted anilines show a quantitative turn-on fluorescence response towards bovine serum albumin (BSA) with a detection limit in the order of micrograms per liter. Thus, fully substituted anilines show great potential for use as fluorescent probes in BSA sensors.
Recommended Literature
- [1] An interplay between electronic and structural effects on the photoluminescence decay mechanisms in LaPO4·nH2O:Tb3+ and LaPO4:Tb3+ single-crystal nanorods? M. T. Colomer,S. Díaz-Moreno,A. Tamayo,A. L. OrtizJ. Mater. Chem. C, 2018,6, 12643-12651 10.1039/C8TC03187H
- [2] An atomistic mechanism for the degradation of perovskite solar cells by trapped charge? Eunhak Lim,Jiyoung Heo,Seong Keun KimNanoscale, 2019,11, 11369-11378 10.1039/C9NR02193K
- [3] An integrated system for field analysis of Cd(ii) and Pb(ii) via preconcentration using nano-TiO2/cellulose paper composite and subsequent detection with a portable X-ray fluorescence spectrometer? Xiaofeng LinRSC Adv., 2016,6, 9002-9006 10.1039/C5RA25693C
- [4] An amphipathic trans-acting phosphorothioate RNA element delivers an uncharged phosphorodiamidate morpholino sequence in mdx mouse myotubes? H. V. Jain,D. Verthelyi,S. L. BeaucageRSC Adv., 2017,7, 42519-42528 10.1039/C7RA04247G
- [5] An aptamer-based keypad lock system? Yaqing Liu,Jiangtao Ren,Jing Li,Jiyang Liu,Erkang WangChem. Commun., 2012,48, 802-804 10.1039/C1CC15979H
- [6] An integrated droplet-digital microfluidic system for on-demand droplet creation, mixing, incubation, and sorting? Lab Chip, 2019,19, 524-535 10.1039/C8LC01170B
- [7] An integrated microfluidic platform for sensitive and rapid detection of biological toxins? Robert J. Meagher,Anson V. Hatch,Ronald F. Renzi,Anup K. SinghLab Chip, 2008,8, 2046-2053 10.1039/B815152K
- [8] An apparatus for determining small amounts of alchohol in sour milk and urine Analyst, 1964,89, 272-275 10.1039/AN9648900272
- [9] An alkynylboronatecycloaddition strategy to functionalised benzyne derivatives? James D. Kirkham,Patrick M. Delaney,George J. Ellames,Eleanor C. Row,Joseph P. A. HarrityChem. Commun., 2010,46, 5154-5156 10.1039/C0CC01345E
- [10] An Aptamer Bio-barCode (ABC) assay using SPR, RNase H, and probes with RNA and gold-nanorods for anti-cancer drug screening Chengbin Yang,Hing Lun Tsang,Pui Man Lau,Ken-Tye Yong,Ho Pui Ho,Siu Kai KongAnalyst, 2017,142, 3579-3587 10.1039/C7AN01026E
Journal Name:Materials Chemistry Frontiers
research_products
-
CAS no.: 89640-58-4