Background correction has been shown to be an effective and indispensable modification in the spectrophotometric determination of ascorbic acid. The decomposition of ascorbic acid in pharmaceutical samples was carried out by incubation with sodium hydroxide to give products that were insensitive to ultraviolet light. The rapid oxidation in air of ascorbic acid, especially in dilute solutions, was avoided by the use of the flow injection principle for spectrophotometric determination and by employing a carrier stream of an anti-oxidizing nature consisting of 6 μg ml–1 of 2-mercaptoethanol in 0.25% sulphuric acid. The optimized method with a single channel manifold made use of a carrier stream flow rate of 1.1 ml min–1, an injection volume of 50 μl, a delay coil of 50 cm (0.5 mm i.d.) and detection at 245 nm. The throughput was at least 180 injections h–1. The proposed flow injection method yielded results for the analysis of 0–20 μg ml–1 of ascorbic acid that were 99–102%(relative standard deviation 0.6% or better) in agreement with those produced by comparable methods involving titration with iodine, chloranil or 2,6-dichlorophenolindophenol [4-(2,6-dichloro-4-hydroxyphenylimino)cyclohexa-2,5-dienone], and high-performance liquid chromatography. When the agreement was not good (as low as 14% with respect to the method being compared), this was traced to the presence of substances which are known to interfere in one or other of the methods of comparison.
Recommended Literature
- [1] Excitable dynamics in the bromate–sulfite–ferrocyanide reaction J. Zagora,M. Vosla?,L. Schreiberová,I. SchreiberPhys. Chem. Chem. Phys., 2002,4, 1284-1291 10.1039/B110048C
- [2] Dissolution of cork biopolymers in biocompatible ionic liquids Helga Garcia,Rui Ferreira,Marija Petkovic,Jamie L. Ferguson,Maria C. Leit?o,H. Q. Nimal Gunaratne,Luís Paulo N. RebeloGreen Chem., 2010,12, 367-369 10.1039/B922553F
- [3] Establishing the accuracy of position-specific carbon isotope analysis of propane by GC-pyrolysis-GC-IRMS ChangjieLiu,PengLiu,XiaofengWang,XiaoqiangLi,JuskeHorita 10.1002/rcm.9494
- [4] Emulsion soft templating of carbide-derived carbon nanospheres with controllable porosity for capacitive electrochemical energy storage? M. Zeiger,N. J?ckel,P. Strubel,L. Borchardt,R. Reinhold,W. Nickel,J. Eckert,V. Presser,S. KaskelJ. Mater. Chem. A, 2015,3, 17983-17990 10.1039/C5TA03730A
- [5] Evidence of rutile-to-anatase photo-induced electron transfer in mixed-phase TiO2 by solid-state NMR spectroscopy? Weili Dai,Guangjun Wu,Michael HungerChem. Commun., 2015,51, 13779-13782 10.1039/C5CC04971G
- [6] Excellent mechanical performance and enhanced dielectric properties of OBC/SiO2 elastomeric nanocomposites: effect of dispersion of the SiO2 nanoparticles? Xing Zhao,Lu Bai,Rui-Ying Bao,Zheng-Ying Liu,Ming-Bo Yang,Wei YangRSC Adv., 2017,7, 46297-46305 10.1039/C7RA08074C
- [7] Excited state potential energy surfaces and their interactions in FeIVO active sites Shaun D. Wong,Edward I. SolomonDalton Trans., 2014,43, 17567-17577 10.1039/C4DT01366B
- [8] Excimer–monomer switch: a reaction-based approach for selective detection of fluoride? Qiao Song,Angela Bamesberger,Lingyun Yang,Haley Houtwed,Haishi CaoAnalyst, 2014,139, 3588-3592 10.1039/C4AN00522H
- [9] Evolution in surface coverage of CH3NH3PbI3?XClXvia heat assisted solvent vapour treatment and their effects on photovoltaic performance of devices Dhirendra K. Chaudhary,Pramendra Kumar,Lokendra KumarRSC Adv., 2016,6, 94731-94738 10.1039/C6RA18729C
- [10] Excimer emission and magnetoluminescence of radical-based zinc(ii) complexes doped in host crystals? Shojiro Kimura,Tetsuro KusamotoChem. Commun., 2020,56, 11195-11198 10.1039/D0CC04830E
Journal Name:ANALYSTANALYST
research_products
-
CAS no.: 89640-58-4