Signal enhancement and low oxidation potentials for miniaturized ECL biosensors via N-butyldiethanolamine
Analyst Pub Date: 2017-05-15 DOI: 10.1039/C7AN00261K
Abstract
We present studies on ruthenium-based electrochemiluminescence (ECL) focusing on conditions supporting signal enhancement and low oxidation potentials. Low oxidation potentials (LOPs) are especially attractive for miniaturized ECL biosensors, as microfabricated electrodes tend to detach from their support when used with high currents and operated at high potentials. Furthermore, high potentials or current densities can lead to damage of typical biosensor surface coatings and biological probes. The possibility of generating LOP ECL signals at a potential below 900 mV was therefore studied for Ru(bpy)32+ with two typical coreactants, i.e. 2-(dibutylamino)ethanol (DBAE) and tripropylamine (TPA), as well as with the tertiary amine N-butyldiethanolamine (NBEA). Furthermore, the effect of buffer components and pH values on ECL signal generation was investigated. We could show a significant LOP ECL signal for NBEA. We found that Tris buffer, with its ability to form complexes with transition metal ions, has a positive influence on this ECL signal in terms of signal strength and LOP capabilities. Specifically, at basic pH values significant increases in ECL signals were observed at 900 mV and at 1.2 V. In fact, the ECL signal at 1.2 V was three times higher than the signal observed in phosphate buffer at a pH of 7, and it was thirty times higher than the ECL signal for TPA under these conditions. The LOP signal for NBEA in Tris buffer at pH 8.5 was similar to the signal obtained for TPA in phosphate buffer at pH 8.5 but three times higher than for TPA at pH 7.0. Interestingly, the coreactant DBAE was neither significantly influenced by the buffer system or pH nor did it present a valuable LOP ECL signal. Finally, it was found that high peak currents in cyclic voltammograms are not the indicators for high ECL signals, which should be obvious because the ECL mechanism requires more complex electron transfers. Overall, the standard TPA ECL at 1.2 V in phosphate buffer at pH 7.0 can successfully be replaced by NBEA ECL at 900 mV in Tris at pH 8.5 providing significantly higher signals accompanied by more gentle electrochemical conditions.
Recommended Literature
- [1] An anti-leakage liquid metal thermal interface material Kaiyuan Huang,Wangkang Qiu,Meilian Ou,Xiaorui Liu,Zenan Liao,Sheng ChuRSC Adv., 2020,10, 18824-18829 10.1039/D0RA02351E
- [2] An asymmetric supercapacitor based on controllable WO3 nanorod bundle and alfalfa-derived porous carbon? Kanjun Sun,Fengting Hua,Shuzhen Cui,Yanrong Zhu,Hui Peng,Guofu MaRSC Adv., 2021,11, 37631-37642 10.1039/D1RA04788D
- [3] An approach towards the synthesis of novel fused nitrogen tricyclic heterocyclic scaffolds via GBB reaction? Sandip Gangadhar Balwe,Yeon Tae JeongOrg. Biomol. Chem., 2018,16, 1287-1296 10.1039/C7OB02933K
- [4] An amino group functionalized metal–organic framework as a luminescent probe for highly selective sensing of Fe3+ ions? Zhonghua Xiang,Chuanqi Fang,Sanhua Leng,Dapeng CaoJ. Mater. Chem. A, 2014,2, 7662-7665 10.1039/C4TA00313F
- [5] An assessment of strategies for the development of solid-state adsorbents for vehicular hydrogen storage Mark D. Allendorf,Alauddin Ahmed,Tom Autrey,Jeffrey Camp,Eun Seon Cho,Maciej Haranczyk,Abhi Karkamkar,Di-Jia Liu,Katie R. Meihaus,Iffat H. Nayyar,Roman Nazarov,Donald J. Siegel,Vitalie Stavila,Jeffrey J. Urban,Srimukh Prasad Veccham,Brandon C. WoodEnergy Environ. Sci., 2018,11, 2784-2812 10.1039/C8EE01085D
- [6] An aptasensor for the detection of ampicillin in milk using a personal glucose meter Xixi Li,Nanwei Zhu,Ruohan Li,Qinpu ZhangAnal. Methods, 2020,12, 3376-3381 10.1039/D0AY00256A
- [7] An alkynylboronatecycloaddition strategy to functionalised benzyne derivatives? James D. Kirkham,Patrick M. Delaney,George J. Ellames,Eleanor C. Row,Joseph P. A. HarrityChem. Commun., 2010,46, 5154-5156 10.1039/C0CC01345E
- [8] Acetylcholinesterase amperometric detection system based on a cobalt(II) tetraphenylporphyrin-modified electrode Analyst, 1996,121, 1123-1126 10.1039/AN9962101123
- [9] An assay for the enzyme N-acetyl-β-d-glucosaminidase (NAGase) based on electrochemical detection using screen-printed carbon electrodes (SPCEs) R. M. Pemberton,J. P. Hart,T. T. MottramAnalyst, 2001,126, 1866-1871 10.1039/B104874K
- [10] An anti-ultrasonic-stripping effect in confined micro/nanoscale cavities and its applications for efficient multiscale metallic patterning? Quan Xiang,Yiqin Chen,Zhiqin Li,Kaixi Bi,Guanhua Zhang,Huigao DuanNanoscale, 2016,8, 19541-19550 10.1039/C6NR07585A
Journal Name:Analyst
research_products
-
CAS no.: 89640-58-4