Preconcentration and voltammetric measurement of silver(I) with a carbon paste electrode modified with 2,9-dichloro-1,10-phenanthroline–surfactant
ANALYSTANALYST Pub Date: DOI: 10.1039/AN9941901859
Abstract
A chemically modified carbon paste electrode was prepared by incorporating appropriate amounts of 2,9-dichloro-1,10-phenanthroline and surfactant directly in a paste mixture. The electrode was able to bind silver ions chemically, and gave a better voltammetric response for silver than did ordinary carbon paste electrodes. The response was characterized with respect to paste composition, preconcentration time, silver ion concentration, reproducibility, possible interferences and other variables. The method showed good linearly for 8 × 10–10–5 × 10–7 mol l–1 silver(I) in nitric acid medium. The performance of the electrode was verified by the determination of silver(I) in waste water.
Recommended Literature
- [1] Acentric and chiral heterometallic inorganic–organic hybrid frameworks mediated by alkali or alkaline earth ions: synthesis and NLO properties Huabin Zhang,Shaowu DuCrystEngComm, 2014,16, 4059-4068 10.1039/C3CE42419G
- [2] An atom efficient route to N-aryl and N-alkyl pyrrolines by transition metal catalysis? Supaporn Sawadjoon,Joseph S. M. SamecOrg. Biomol. Chem., 2011,9, 2548-2554 10.1039/C0OB00383B
- [3] An amphipathic trans-acting phosphorothioate RNA element delivers an uncharged phosphorodiamidate morpholino sequence in mdx mouse myotubes? H. V. Jain,D. Verthelyi,S. L. BeaucageRSC Adv., 2017,7, 42519-42528 10.1039/C7RA04247G
- [4] An algal process treatment combined with the Fenton reaction for high concentrations of amoxicillin and cefradine Haitao Li,Yu Pan,Zhizhi Wang,Shan Chen,Ruixin Guo,Jianqiu ChenRSC Adv., 2015,5, 100775-100782 10.1039/C5RA21508K
- [5] An apparatus for determining small amounts of alchohol in sour milk and urine Analyst, 1964,89, 272-275 10.1039/AN9648900272
- [6] An alumina stabilized graphene oxide wrapped SnO2 hollow sphere LIB anode with improved lithium storage? Xiang Liu,Qian Sun,A. B. Djuri?i?,Maohai Xie,Baohu Dai,Jinyao Tang,Charles Surya,Changzhong Liao,Kaimin ShihRSC Adv., 2015,5, 100783-100789 10.1039/C5RA22482A
- [7] An investigation of the electrochemical delithiation process of carbon coated α-Fe2O3nanoparticles Adrian Brandt,Florian Winter,Sebastian Klamor,Frank Berkemeier,Jatinkumar Rana,Rainer P?ttgen,Andrea BalducciJ. Mater. Chem. A, 2013,1, 11229-11236 10.1039/C3TA11821E
- [8] An apparatus for testing water by measurement of its electrical conductivity Analyst, 1912,37, 538-543 10.1039/AN9123700538
- [9] An anti-leakage liquid metal thermal interface material Kaiyuan Huang,Wangkang Qiu,Meilian Ou,Xiaorui Liu,Zenan Liao,Sheng ChuRSC Adv., 2020,10, 18824-18829 10.1039/D0RA02351E
- [10] An analyte-triggered artificial peroxidase system based on dimanganese complex for a versatile enzyme assay? Suji Lee,Min Su HanChem. Commun., 2021,57, 9450-9453 10.1039/D1CC03638F
Journal Name:ANALYSTANALYST
research_products
-
CAS no.: 89640-58-4