A simple, sensitive, high-resolution, customized, reverse phase ultra-high performance liquid chromatographic method for related substances of a therapeutic peptide (bivalirudin trifluoroacetate) using the quality by design approach
Analytical MethodsANAL METHODS-UK Pub Date: 2019-11-22 DOI: 10.1039/C9AY01998G
Abstract
Among all chemical sameness characterization tests of Therapeutic Peptides (TPs), one of the most significant and challenging aspects is to demonstrate comparable impurity profiles (both qualitative & quantitative) between a generic product and reference listed drug (RLD). Though multiple state of the art orthogonal analytical methods are being used for the identification and quantification of related impurities in TPs, it is important that the developed methods are simple, selective, and sensitive, and can be easily implementable in quality control laboratories. The current published chromatographic (HPLC or UHPLC) methods for the quantification of related substances in TPs rarely use non-mass spectrometry compatible ion pairing reagents (NMS-IPRs) in the mobile phase composition over mass spectrometry compatible ion pairing reagents (MS-IPRs), due to their compatibility issues with high-resolution mass-based detection methods. We hypothesize that achieving mixed mode stationary phase characteristics using hydrophobic NMS-IPRs such as sodium 1-butanesulfonate, at concentrations <10 mM in the diethanolammonium phosphate buffer (pH 2.9) on a C-18 stationary phase, would be able to resolve critical impurities such as Penta-Gly, D-Asn, and Tri-Gly using the single UHPLC method, and is also selective to all other related impurities of bivalirudin (BIV) cited in the literature. Furthermore, customization of column dimensions (300 mm × 2.1 mm × 1.8 μm) helped in achieving a resolution (Rs) > 2.0 between Penta-Gly & BIV, and a peak to valley ratio (Hp/Hv) > 4.0 between BIV & D-Asn and D-Asn & Tri-Gly impurities. The developed method is sensitive (LOQ ~ 0.05% with respect to analyte concentration), precise, accurate, and linear in the range of 1 μg mL?1 to 2500 μg mL?1. This method is rugged, robust, and easily implementable in quality control laboratories for monitoring the related impurities of bivalirudin.
Recommended Literature
- [1] Dissolution of cork biopolymers in biocompatible ionic liquids Helga Garcia,Rui Ferreira,Marija Petkovic,Jamie L. Ferguson,Maria C. Leit?o,H. Q. Nimal Gunaratne,Luís Paulo N. RebeloGreen Chem., 2010,12, 367-369 10.1039/B922553F
- [2] Emerging 2D hybrid nanomaterials: towards enhanced sensitive and selective conductometric gas sensors at room temperature Hanie Hashtroudi,Ian D. R. MackinnonJ. Mater. Chem. C, 2020,8, 13108-13126 10.1039/D0TC01968B
- [3] Dissociative electron attachment to HGaF4 Lewis–Br?nsted superacid Marcin Czapla,Jack SimonsPhys. Chem. Chem. Phys., 2018,20, 21739-21745 10.1039/C8CP04007A
- [4] Empowering microfluidics by micro-3D printing and solution-based mineral coating? Hongxia Li,Aikifa Raza,Qiaoyu Ge,Jin-You Lu,TieJun ZhangSoft Matter, 2020,16, 6841-6849 10.1039/D0SM00958J
- [5] Excimer–monomer switch: a reaction-based approach for selective detection of fluoride? Qiao Song,Angela Bamesberger,Lingyun Yang,Haley Houtwed,Haishi CaoAnalyst, 2014,139, 3588-3592 10.1039/C4AN00522H
- [6] Establishing the accuracy of position-specific carbon isotope analysis of propane by GC-pyrolysis-GC-IRMS ChangjieLiu,PengLiu,XiaofengWang,XiaoqiangLi,JuskeHorita 10.1002/rcm.9494
- [7] Dissociation of large gaseous serine clusters produces abundant protonated serine octamer Jacob S. Jordan,Evan R. WilliamsAnalyst, 2021,146, 2617-2625 10.1039/D1AN00273B
- [8] Fast synthesis of red Li3BaSrLn3(WO4)8:Eu3+ phosphors for white LEDs under near-UV excitation by a microwave-assisted solid state reaction method and photoluminescence studies Bo Wei,Zhenyu Liu,Chen Xie,Shu Yang,Wentao Tang,Aiwei Gu,Wing-Tak Wong,Ka-Leung WongJ. Mater. Chem. C, 2015,3, 12322-12327 10.1039/C5TC03165F
- [9] Emerging investigator series: first-principles and thermodynamics comparison of compositionally-tuned delafossites: cation release from the (001) surface of complex metal oxides? Joseph W. Bennett,Diamond T. Jones,Blake G. Hudson,Joshua Melendez-Rivera,Robert J. Hamers,Sara E. MasonEnviron. Sci.: Nano, 2020,7, 1642-1651 10.1039/C9EN01304K
- [10] Exceptionally high temperature spin crossover in amide-functionalised 2,6-bis(pyrazol-1-yl)pyridine iron(ii) complex revealed by variable temperature Raman spectroscopy and single crystal X-ray diffraction? Max Attwood,Hiroki Akutsu,Lee Martin,Toby J. Blundell,Pierre Le Maguere,Scott S. TurnerDalton Trans., 2021,50, 11843-11851 10.1039/D1DT01743H
Journal Name:Analytical MethodsANAL METHODS-UK
research_products
-
CAS no.: 89640-58-4