On-line deoxygenation for reductive electrochemical detection of artemisinin and dihydroartemisinin in liquid chromatography
Analyst Pub Date: DOI: 10.1039/A706112I
Abstract
A straightforward method for the deoxygenation of mobile phases and samples required for reductive detection in liquid chromatography is described. The method, which is based on the use of a commercially available on-line deoxygenator placed between the column and the detector, eliminates the problems associated with separate deoxygenations of the mobile phase and samples and restrictions imposed by work in an oxygen-free environment. The method is compatible with determinations of artemisinin and its main metabolite, dihydroartemisinin, and also artelinate, in liquid samples. With the deoxygenator, efficiencies of the order of 4000–10 000 theoretical plates were obtained for artemisinin using 3.0, 4.0 and 4.6 mm diameter columns. The extra-column band broadening due to the deoxygenator was not found to be a limiting factor. Amperometric detection with a gold electrode gave rise to lower background currents and better peak current reproducibilities than that with glassy carbon and gold amalgam electrodes. The relative standard deviations in the peak current for 10 injections of 100 pmol of artemisinin, dihydroartemisinin and artelinate were 3.0, 1.4 and 3.3%, respectively. The peak currents for the compounds depended linearly on the amount injected in the range 10–200 pmol and the detection limits for artemisinin and dihydroartemisinin were calculated to be 2 and 3 pmol, respectively.
Recommended Literature
- [1] Emulsion soft templating of carbide-derived carbon nanospheres with controllable porosity for capacitive electrochemical energy storage? M. Zeiger,N. J?ckel,P. Strubel,L. Borchardt,R. Reinhold,W. Nickel,J. Eckert,V. Presser,S. KaskelJ. Mater. Chem. A, 2015,3, 17983-17990 10.1039/C5TA03730A
- [2] Examination of the hydrogen-bonding networks in small water clusters (n = 2–5, 13, 17) using absolutely localized molecular orbital energy decomposition analysis? Erika A. Cobar,Paul R. Horn,Robert G. Bergman,Martin Head-GordonPhys. Chem. Chem. Phys., 2012,14, 15328-15339 10.1039/C2CP42522J
- [3] Evidence that the availability of an allylic hydrogen governs the regioselectivity of the Wacker oxidation Matthew J. Gaunt,Jinquan Yu,Jonathan B. SpencerChem. Commun., 2001, 1844-1845 10.1039/B103066N
- [4] Emulsion technologies for multicellular tumour spheroid radiation assays? Kay S. McMillan,Anthony G. McCluskey,Annette Sorensen,Marie Boyd,Michele ZagnoniAnalyst, 2016,141, 100-110 10.1039/C5AN01382H
- [5] Fate of nitrogen-15 in the subsequent growing season of greenhouse tomato plants (Lycopersicon esculentum Mill) as influenced by alternate partial root-zone irrigation Maomao Hou,Fenglin Zhong,Qiu Jin,Enjiang Liu,Jie Feng,Tengyun Wang,Yue GaoRSC Adv., 2017,7, 34392-34400 10.1039/C7RA05271E
- [6] Evolutionary de novo design of phenothiazine derivatives for dye-sensitized solar cells? Vishwesh Venkatraman,Marco Foscato,Vidar R. Jensen,Bj?rn K?re AlsbergJ. Mater. Chem. A, 2015,3, 9851-9860 10.1039/C5TA00625B
- [7] Excimer–monomer switch: a reaction-based approach for selective detection of fluoride? Qiao Song,Angela Bamesberger,Lingyun Yang,Haley Houtwed,Haishi CaoAnalyst, 2014,139, 3588-3592 10.1039/C4AN00522H
- [8] Excellent energy storage performance in NaNbO3-based relaxor antiferroeic ceramics under a low electric field XuxinCheng,XiaomingChen,PengyuanFan 10.1007/s10832-022-00283-w
- [9] Dissolution of cork biopolymers in biocompatible ionic liquids Helga Garcia,Rui Ferreira,Marija Petkovic,Jamie L. Ferguson,Maria C. Leit?o,H. Q. Nimal Gunaratne,Luís Paulo N. RebeloGreen Chem., 2010,12, 367-369 10.1039/B922553F
- [10] Enabling chloride salts for thermal energy storage: implications of salt purity? J. Matthew Kurley,Phillip W. Halstenberg,Abbey McAlister,Stephen Raiman,Richard T. MayesRSC Adv., 2019,9, 25602-25608 10.1039/C9RA03133B
Journal Name:Analyst
research_products
-
CAS no.: 89640-58-4