One-step extraction prior to two-step detection by ultra high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) to determine different groups of antibacterial agents in infant disposable hygiene products
Analytical Methods Pub Date: 2016-12-12 DOI: 10.1039/C6AY03220F
Abstract
One-step extraction prior to a two-step detection method based on UHPLC-MS/MS was developed to determine seven quaternary ammonium salts (QACs), three isothiazolinone antibacterial agents and seven phenolic antibacterial agents in infant disposable hygiene products. Samples were ultrasonically extracted by acetonitrile; the extraction solution was directly used to separate seven QACs on a hydrophilic chromatographic column (HILIC column) by isocratic elution (0.1% formic acid acetonitrile and 10 mmol L?1 ammonium acetate solution as the mobile phases). QACs were then detected in multiple reaction monitoring (MRM) of MS/MS under an electro-spray ionization source in positive mode (ESI+). For the remaining ten analytes, the extraction solution was dried by nitrogen gas blowing and re-dissolved with acidulated methanol water solution. Then they were separated on a C18 chromatographic column with gradient elution program using methanol and water as mobile phases. Finally, ten analytes were simultaneously ionized by using a electro-spray source in positive and negative modes and acquisition was achieved in MRM. The developed methods were validated in terms of the method limit of detection and quantitation (MLOD and MLOQ), matrix effects, recovery and precision. Results indicated that favorable linear relations (r > 0.997) were obtained over the selected concentration ranges of 0.1–50 μg L?1, 1.0–500 μg L?1 and 50–2000 μg L?1 for QACs, isothiazolinone antibacterial agents and phenolic antibacterial agents, respectively. The MLODs of the three groups of antibacterial agents were 0.8 μg kg?1, 1.5–6.5 μg kg?1 and 200–500 μg kg?1, respectively. Recoveries were calculated at three concentration levels spiked in negative paper diaper samples and the values were found between 83.7% and 112% with relative standard deviation (RSD) values less than 13% for intra-day precision (n = 6) and less than 16% for inter-day precision (n = 5). The developed and validated methods were successfully applied to determine the concentrations of antibacterial agents in real samples and QACs and isothiazolinone antibacterial agents were detected in several samples. These methods are rapid, sensitive and suitable for the determination of antibacterial agents in infant disposable hygiene products and some other similar products.
Recommended Literature
- [1] Ester-directed orthogonal dual C–H activation and ortho aryl C–H alkenylation via distal weak coordination? Manickam Bakthadoss,Tadiparthi Thirupathi Reddy,Vishal Agarwal,Duddu S. SharadaChem. Commun., 2022,58, 1406-1409 10.1039/D1CC06097J
- [2] Exciton manipulation in rippled transition metal dichalcogenides? Chen Long,Ying Dai,Jianwei Li,Hao JinNanoscale, 2020,12, 21124-21130 10.1039/D0NR05602B
- [3] Emerging investigators Polym. Chem., 2015,6, 5501-5502 10.1039/C5PY90111A
- [4] Evolution of shape, size, and areal density of a single plane of Si nanocrystals embedded in SiO2 matrix studied by atom probe tomography Bin Han,Yasuo Shimizu,Gabriele Seguini,Celia Castro,Gérard Ben Assayag,Koji Inoue,Yasuyoshi Nagai,Sylvie Schamm-Chardon,Michele PeregoRSC Adv., 2016,6, 3617-3622 10.1039/C5RA26710B
- [5] Emerging investigator series: first-principles and thermodynamics comparison of compositionally-tuned delafossites: cation release from the (001) surface of complex metal oxides? Joseph W. Bennett,Diamond T. Jones,Blake G. Hudson,Joshua Melendez-Rivera,Robert J. Hamers,Sara E. MasonEnviron. Sci.: Nano, 2020,7, 1642-1651 10.1039/C9EN01304K
- [6] Evolutionary de novo design of phenothiazine derivatives for dye-sensitized solar cells? Vishwesh Venkatraman,Marco Foscato,Vidar R. Jensen,Bj?rn K?re AlsbergJ. Mater. Chem. A, 2015,3, 9851-9860 10.1039/C5TA00625B
- [7] Enabling stable MnO2 matrix for aqueous zinc-ion battery cathodes? Yiding Jiao,Liqun Kang,Jasper Berry-Gair,Kit McColl,Jianwei Li,Haobo Dong,Hao Jiang,Ryan Wang,Furio Corà,Dan J. L. Brett,Ivan P. ParkinJ. Mater. Chem. A, 2020,8, 22075-22082 10.1039/D0TA08638J
- [8] Fe3O4/PEG-SO3H as a heterogeneous and magnetically-recyclable nanocatalyst for the oxidation of sulfides to sulfones or sulfoxides Saeideh Mirfakhraei,Malak Hekmati,Fereshteh Hosseini Eshbala,Hojat VeisiNew J. Chem., 2018,42, 1757-1761 10.1039/C7NJ02513K
- [9] Excitation energies from ground-state density-functionals by means of generator coordinates A. B. F. da Silva,K. CapellePhys. Chem. Chem. Phys., 2009,11, 4564-4569 10.1039/B902529D
- [10] Esterase-responsive polymeric prodrug-based tumor targeting nanoparticles for improved anti-tumor performance against colon cancer? Gang Pan,Yi-jie Bao,Jie Xu,Tao Liu,Cheng Liu,Yan-yan Qiu,Xiao-jing Shi,Hui Yu,Ting-ting Jia,Xia Yuan,Ze-ting Yuan,Yi-jun CaoRSC Adv., 2016,6, 42109-42119 10.1039/C6RA05236C
Journal Name:Analytical Methods
research_products
-
CAS no.: 89640-58-4