Effect of sodium dodecyl sulphate and Brij-35 on the analysis of sulphonamides in physiological samples using direct injection and acetonitrile gradients
Analytical Methods Pub Date: 2016-04-13 DOI: 10.1039/C6AY00390G
Abstract
Micellar liquid chromatography (MLC) is a reversed-phase (RP) mode, which often does not require gradient elution, since the peaks of mixtures of compounds within a large range of polarities appear more evenly distributed in the chromatograms of isocratic elution, giving rise to a “gradient effect”. However, the use of a gradient of organic solvent may still be convenient to shorten the total analysis time. This work compares the separation of 15 sulphonamides using conventional hydro-organic RPLC and MLC with the surfactants sodium dodecyl sulphate (SDS) and Brij-35, and both isocratic and gradient elution with acetonitrile. The observed behaviour is rationalized attending to the interactions in the different environments formed inside the chromatographic column, in the absence and presence of the two surfactants. The retention of alkylbenzenes is used to evaluate the relative polarity of the stationary phase under hydro-organic and micellar conditions. The most favourable gradients in MLC were used to analyse the sulphonamides in milk and urine samples, directly injected into the chromatograph. The addition of an initial step of a micellar mobile phase containing only SDS or Brij-35 facilitated the direct injection of the sample, which was followed by a gradient of acetonitrile to elute the most retained compounds.
Recommended Literature
- [1] An approach for correlating the structural and electrical properties of Zr4+-modified SrBi4Ti4O15/SBT ceramic Priyambada Nayak,Tanmaya Badapanda,Anil Kumar Singh,Simanchalo PanigrahiRSC Adv., 2017,7, 16319-16331 10.1039/C7RA00366H
- [2] An Aptamer Bio-barCode (ABC) assay using SPR, RNase H, and probes with RNA and gold-nanorods for anti-cancer drug screening Chengbin Yang,Hing Lun Tsang,Pui Man Lau,Ken-Tye Yong,Ho Pui Ho,Siu Kai KongAnalyst, 2017,142, 3579-3587 10.1039/C7AN01026E
- [3] Alternative mixtures to R-600a. Theoretical assessment and experimental energy evaluation of binary mixtures in a commercial cooler: Mélanges alternatifs au R-600a. évaluation théorique et évaluation énergétique expérimentale de mélanges binaires dans un refroidisseur commercial. DanielCalleja-Anta,DanielSánchez,LauraNebot-Andres,RamónCabello,RodrigoLlopis 10.1016/j.ijrefrig.2023.05.009
- [4] An atlas of endohedral Sc2S cluster fullerenes? Li-Hua Gan,Rui Wu,Jian-Lei Tian,Patrick W. FowlerPhys. Chem. Chem. Phys., 2017,19, 419-425 10.1039/C6CP07370K
- [5] Alumina coating on 5 V lithium cobalt fluorophosphate cathode material for lithium secondary batteries – synthesis and electrochemical properties? S. Amaresh,K. Karthikeyan,K. J. Kim,Y. S. LeeRSC Adv., 2014,4, 23107-23115 10.1039/C4RA02318H
- [6] An arsenic trioxide nanoparticle prodrug (ATONP) potentiates a therapeutic effect on an aggressive hepatocellular carcinoma model via enhancement of intratumoral arsenic accumulation and disturbance of the tumor microenvironment? Xin Fu,Qing-rong Liang,Rong-guang Luo,Yan-shu Li,Xiao-ping Xiao,Lu-lu Yu,Wen-zhe Shan,Guang-qin FanJ. Mater. Chem. B, 2019,7, 3088-3099 10.1039/C9TB00349E
- [7] An analyte-triggered artificial peroxidase system based on dimanganese complex for a versatile enzyme assay? Suji Lee,Min Su HanChem. Commun., 2021,57, 9450-9453 10.1039/D1CC03638F
- [8] An approach to C–N activation: coupling of arenesulfonyl hydrazides and arenesulfonyl chlorides with tert-amines via a metal-, oxidant- and halogen-free anodic oxidation?? M. Sheykhan,S. Khani,S. Shaabanzadeh,M. JoafshanGreen Chem., 2017,19, 5940-5948 10.1039/C7GC03141F
- [9] An amphoteric reactivity of a mixed-valent bis(μ-oxo)dimanganese(iii,iv) complex acting as an electrophile and a nucleophile? Muniyandi Sankaralingam,So Hyun Jeon,Yong-Min Lee,Mi Sook Seo,Wonwoo NamDalton Trans., 2016,45, 376-383 10.1039/C5DT04292E
- [10] An Appraisal of pH triggered Bacitracin drug release, through composite hydrogel systems RabailGul,MariamMir,MurtazaNAli 10.1177/08853282231160212
Journal Name:Analytical Methods
research_products
-
CAS no.: 89640-58-4