A high-throughput BIA-MPA method for the simultaneous determination of amiloride and furosemide
Analytical Methods Pub Date: 2016-10-14 DOI: 10.1039/C6AY02506D
Abstract
In this work, a simple and fast batch injection analysis system with multiple pulse amperometric detection (BIA-MPA) was developed for the simultaneous determination of amiloride (AMD) and furosemide (FMD). A sample plug (150 μL) was directly injected into the unmodified boron-doped diamond (BDD) electrode immersed in 0.1 mol L?1 borate buffer (pH = 10). Simple and fast sample pre-treatment steps were required (dissolution and dilution). The analytical characteristics of the proposed method include good stability (RSD < 1.1%; n = 20), low detection limits (0.13 and 0.94 mg L?1 for AMD and FMD, respectively), high throughput (72 injections per h) and minimal waste production (~150 μL by analysis). The results obtained with the BIA-MPA method were compared to those obtained by HPLC; similar results were obtained (at a 95% confidence level).
Recommended Literature
- [1] Excellent peroxidase mimicking property of CuO/Pt nanocomposites and their application as an ascorbic acid sensor? Xinhuan Wang,Shuangfei Cai,Cui QiAnalyst, 2017,142, 2500-2506 10.1039/C7AN00589J
- [2] Excimer emission and magnetoluminescence of radical-based zinc(ii) complexes doped in host crystals? Shojiro Kimura,Tetsuro KusamotoChem. Commun., 2020,56, 11195-11198 10.1039/D0CC04830E
- [3] Excitable dynamics in the bromate–sulfite–ferrocyanide reaction J. Zagora,M. Vosla?,L. Schreiberová,I. SchreiberPhys. Chem. Chem. Phys., 2002,4, 1284-1291 10.1039/B110048C
- [4] Fate of Sb(v) and Sb(iii) species along a gradient of pH and oxygen concentration in the Carnoulès mine waters (Southern France) Eléonore Resongles,Corinne Casiot,Fran?oise Elbaz-Poulichet,Rémi Freydier,Odile Bruneel,Christine Piot,Sophie Delpoux,Aurélie Volant,Angélique DesoeuvreEnviron. Sci.: Processes Impacts, 2013,15, 1536-1544 10.1039/C3EM00215B
- [5] Etching of glass microchips with supercritical water? Pavel Karásek,Jakub Grym,Michal Roth,Josef Planeta,Franti?ek ForetLab Chip, 2015,15, 311-318 10.1039/C4LC00843J
- [6] Esterase-responsive polymeric prodrug-based tumor targeting nanoparticles for improved anti-tumor performance against colon cancer? Gang Pan,Yi-jie Bao,Jie Xu,Tao Liu,Cheng Liu,Yan-yan Qiu,Xiao-jing Shi,Hui Yu,Ting-ting Jia,Xia Yuan,Ze-ting Yuan,Yi-jun CaoRSC Adv., 2016,6, 42109-42119 10.1039/C6RA05236C
- [7] Distinct roles of SNARE-mimicking lipopeptides during initial steps of membrane fusion? Alena Koukalová,?árka Pokorná,Aimee L. Boyle,Nestor Lopez Mora,Alexander Kros,Martin Hof,Radek ?achlNanoscale, 2018,10, 19064-19073 10.1039/C8NR05730C
- [8] Embedding cyclic nitrone in mesoporous silica particles for EPR spin trapping of superoxide and other radicals? Eric Besson,Stéphane Gastaldi,Emily Bloch,Selma Aslan,Hakim Karoui,Olivier Ouari,Micael HardyAnalyst, 2019,144, 4194-4203 10.1039/C9AN00468H
- [9] Evidence for the intrinsic nature of band-gap states electrochemically observed on atomically flat TiO2(110) surfaces? Shintaro Takata,Yoshihiro MiuraPhys. Chem. Chem. Phys., 2014,16, 24784-24789 10.1039/C4CP03280B
- [10] Enantiomorphic symmetry breaking in crystallization of molten sodium chlorate? Martin R. Ward,Gary W. Copeland,Andrew J. AlexanderChem. Commun., 2010,46, 7634-7636 10.1039/C0CC02563A
Journal Name:Analytical Methods
research_products
-
CAS no.: 89640-58-4